The Journal of hospital infection · 2017
An in-vitro urinary catheterization model that approximates clinical conditions for evaluation of innovations to prevent catheter-associated urinary tract infections.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chua R Y R, Lim K, Leong S S J, Tambyah P A, Ho B
Аннотация
BACKGROUND: Catheter-associated urinary tract infections (CAUTI) account for approximately 25% of nosocomial infections globally, and often result in increased morbidity and healthcare costs. An additional concern is the presence of microbial biofilms which are major reservoirs of bacteria, especially antibiotic-resistant bacteria, in catheters. Since introduction of the use of closed drainage systems, innovations to combat CAUTI have not led to significant improvements in clinical outcomes. The lack of a robust laboratory platform to test new CAUTI preventive strategies may impede development of novel technologies.
AIM: To establish an in-vitro catheterization model (IVCM) for testing of technological innovations to prevent CAUTI.
METHODS: The IVCM consists of a continuous supply of urine medium flowing into a receptacle (bladder) where the urine is drained through a urinary catheter connected to an effluent collection vessel (drainage bag). Test organism(s) can be introduced conveniently into the bladder via a rubber septa port. Development of bacteriuria and microbial biofilm on the catheter can be determined subsequently.
FINDINGS: With an initial inoculum of Escherichia coli [∼5×105 colony-forming units (cfu)/mL] into the bladder, a 100% silicone catheter and a commercially available silver-hydrogel catheter showed heavy biofilm colonization (∼108 cfu/cm and ∼107 cfu/cm, respectively) with similar bacterial populations in the urine (bacteriuria) (∼108 cfu/mL and ∼107 cfu/mL, respectively) within three days. Interestingly, an antimicrobial peptide (CP11-6A)-coated catheter showed negligible biofilm colonization and no detectable bacteriuria.
CONCLUSION: The IVCM is a useful preclinical approach to evaluate new strategies for the prevention of CAUTI.
AIM: To establish an in-vitro catheterization model (IVCM) for testing of technological innovations to prevent CAUTI.
METHODS: The IVCM consists of a continuous supply of urine medium flowing into a receptacle (bladder) where the urine is drained through a urinary catheter connected to an effluent collection vessel (drainage bag). Test organism(s) can be introduced conveniently into the bladder via a rubber septa port. Development of bacteriuria and microbial biofilm on the catheter can be determined subsequently.
FINDINGS: With an initial inoculum of Escherichia coli [∼5×105 colony-forming units (cfu)/mL] into the bladder, a 100% silicone catheter and a commercially available silver-hydrogel catheter showed heavy biofilm colonization (∼108 cfu/cm and ∼107 cfu/cm, respectively) with similar bacterial populations in the urine (bacteriuria) (∼108 cfu/mL and ∼107 cfu/mL, respectively) within three days. Interestingly, an antimicrobial peptide (CP11-6A)-coated catheter showed negligible biofilm colonization and no detectable bacteriuria.
CONCLUSION: The IVCM is a useful preclinical approach to evaluate new strategies for the prevention of CAUTI.