BACKGROUND

Urinary tract infections (UTIs) are the most commonly reported health care-associated infection (HAI) in the United States. Among UTIs acquired in the hospital, approximately 75% are associated with urinary catheters, with an estimated 15%-25% of all hospitalized patients receiving urinary catheters during their hospitalization. Despite ambitious national goals to reduce these infections, catheter-associated urinary tract infection (CAUTI) has not decreased in the United States.

METHODS

Systems engineering (SE) and human factors engi- neering (HFE) methods were used to reduce urinary catheter utilization and CAUTIs in a three-year (June 1, 2012-May 31, 2015) quality improvement project in a 610-bed academic medical center. These methods were used to define the factors leading to CAUTI and promote standardization of urinary catheter utilization, insertion, and maintenance.

RESULTS

The total systemwide CAUTI count decreased from 135 cases at baseline to 74 cases at the end of the project's Year 1, to 59 cases at the end of Year 2, and 25 cases at the end of Year 3-alone, an 81.5% reduction from baseline. The control chart showed a steady decline in the CAUTI count within a few months after the project's start. By the end of Year 3, on the basis of an average attributable-per-patient cost of CAUTI ($1,007 per case), the estimated annual avoidable CAUTI costs decreased from approximately $135,945 to $25,175 per year. Urinary catheter utilization decreased by 27.3% during the same three-year period, and the systemwide CAUTI standardized infection ratio (SIR) decreased from 3.2 to 0.51 (84.1% from baseline).

CONCLUSION

SE and HFE methods and principles can effectively decrease urinary catheter utilization and CAUTI incidence in an academic medical center hospital environment.

Для цитирования: Rhee Chanhaeng, Phelps M Eleanor, Meyer Bruce, Reed W Gary. Viewing Prevention of Catheter-Associated Urinary Tract Infection as a System: Using Systems Engineering and Human Factors Engineering in a Quality Improvement Project in an Academic Medical Center.. Joint Commission journal on quality and patient safety. 2016. DOI: 10.1016/s1553-7250(16)42060-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.