Медицинская библиотека · Journal of cardiology · 2015

Low left atrial appendage flow velocity predicts recurrence of atrial fibrillation after catheter ablation of persistent atrial fibrillation.

Kanda Takashi, Masuda Masaharu, Sunaga Akihiro, Fujita Masashi, Iida Osamu, Okamoto Shin, Ishihara Takayuki, Watanabe Tetsuya, Takahara Mitsuyoshi, Sakata Yasushi, Uematsu Masaaki

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Recurrence after catheter ablation of persistent atrial fibrillation (AF) remains an unsolved issue. This study aimed to explore the association between the left atrial appendage peak flow velocity (LAAV) and AF recurrence after ablation in persistent AF patients.

METHODS

Fifty-three consecutive patients who underwent an initial catheter ablation of persistent AF were enrolled [age, 65±10 years; male, 42 (79%)]. The LAAV was obtained by transesophageal echocardiography before ablation. All the patients underwent pulmonary vein isolation and were followed up for 12 months. The LAAV and other clinical factors (AF duration, CHA2DS2VASc score, left atrial diameter, left atrial volume, and left ventricular ejection fraction) were tested using a Cox proportional hazards regression analysis as predictors of AF recurrence during the 1-year follow-up.

RESULTS

AF recurrence occurred in 16 (30%) patients. The patients with AF recurrences had lower LAAVs (23.3±7.2cm/s vs. 33.3±15.1cm/s, p=0.002) than those without AF recurrence. In the multivariable analysis, a low LAAV independently predicted AF recurrence (hazard ratio, 3.04; 95% confidence interval, 1.05-8.79; p=0.040). A Kaplan-Meier analysis also demonstrated a lower survival rate free from AF recurrence in the low LAAV group than in the high LAAV group (p=0.030).

CONCLUSION

A low LAAV was associated with AF recurrence after the initial catheter ablation of persistent AF.

Для цитирования: Kanda Takashi, Masuda Masaharu, Sunaga Akihiro, Fujita Masashi, Iida Osamu, Okamoto Shin, Ishihara Takayuki, Watanabe Tetsuya, Takahara Mitsuyoshi, Sakata Yasushi, Uematsu Masaaki. Low left atrial appendage flow velocity predicts recurrence of atrial fibrillation after catheter ablation of persistent atrial fibrillation.. Journal of cardiology. 2015. DOI: 10.1016/j.jjcc.2015.04.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.