MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2014.04.029

Медицинская библиотека · Heart rhythm · 2014

The mechanical fibrillation pattern of the atrial myocardium is associated with acute and long-term success of electrical cardioversion in patients with persistent atrial fibrillation.

De Vos Cees B, Limantoro Ione, Pisters Ron, Delhaas Tammo, Schotten Ulrich, Cheriex Emile C, Tieleman Robert G, Crijns Harry J G M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Electrophysiological studies demonstrate that a short atrial fibrillation cycle length (AFCL) is related with poor outcome of electrical cardioversion (ECV) of atrial fibrillation (AF). We found previously that the mechanical AFCL (AFCL-tvi) and atrial fibrillatory velocity (AFV-tvi) may be determined noninvasively using color tissue velocity imaging (TVI) and closely relates to the electrophysiological AFCL.

OBJECTIVE

To evaluate the relation between AFCL-tvi, AFV-tvi, and success of ECV in patients with AF.

METHODS

We prospectively studied 133 patients with persistent AF by performing echocardiography before ECV and measured the AFCL-tvi and AFV-tvi in the right atrium and left atrium. Recurrent AF was monitored.

RESULTS

Nineteen (14%) patients had failure of ECV, 42 (32%) remained in sinus rhythm after 1-year follow-up, and 72 (54%) had a recurrence of persistent AF. Patients with immediate ECV failure had a lower median AFV-tvi measured in the right atrium than did patients with a successful ECV: 0.7 cm/s (0.2-1.0 cm/s) vs. 1.7 cm/s (0.9-2.8 cm/s) (P = .008). Patients with maintenance of sinus rhythm after 1 year had a longer AFCL-tvi measured in the left atrium than did patients with recurrence of AF (150 ms vs 137 ms; P = .017) and had a higher AFV-tvi in both atria (1.4 vs. 0.9 cm/s in the left atrium; P = .013 and 2.2 vs 1.4 cm/s in the right atrium; P = .011). Multivariate analyses showed that all atrial TVI parameters were independently associated with the maintenance of sinus rhythm after 1 year.

CONCLUSION

Higher atrial fibrillatory wall velocities and longer AFCLs determined by echocardiography are associated with acute and long-term success of ECV.

Для цитирования: De Vos Cees B, Limantoro Ione, Pisters Ron, Delhaas Tammo, Schotten Ulrich, Cheriex Emile C, Tieleman Robert G, Crijns Harry J G M. The mechanical fibrillation pattern of the atrial myocardium is associated with acute and long-term success of electrical cardioversion in patients with persistent atrial fibrillation.. Heart rhythm. 2014. DOI: 10.1016/j.hrthm.2014.04.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.