BACKGROUND

Radiofrequency catheter ablation guided by electroanatomical mapping is currently an important therapeutic option for the treatment of atrial fibrillation. The complexity of the procedure, the several techniques used and the diversity of the patients hinder the reproduction of the results and the indication for the procedure.

OBJECTIVE

To evaluate the efficacy and factors associated with recurrence of atrial fibrillation.

METHODS

Prospective cohort study with consecutive patients submitted to atrial fibrillation ablation treatment guided by electroanatomical mapping. The inclusion criteria were as follows: minimum age of 18 years; presence of paroxysmal, persistent or long-standing persistent AF; AF recording on an electrocardiogram, exercise testing or Holter monitoring (duration longer than 15 minutes); presence of symptoms associated with AF episodes; AF refractoriness to, at least, two antiarrhythmic drugs, one of which being amiodarone, or impossibility to use antiarrhythmic drugs.

RESULTS

The study included 95 patients (age 55 ± 12 years, 84% men, mean CHADS2 = 0.8) who underwent 102 procedures with a median follow-up of 13.4 months. The recurrence-free rate after the procedure was 75.5% after 12 months. Atrial fibrillation recurred as follows: 26.9% of patients with paroxysmal and persistent atrial fibrillation; 45.8% of patients with long-standing persistent atrial fibrillation (p = 0.04). Of the analyzed variables, the increased size of the left atrium has proven to be an independent predictor of atrial fibrillation recurrence after the procedure (HR = 2.58; 95% CI: 1.26-4.89). Complications occurred in 4.9% of the procedures.

CONCLUSION

Atrial fibrillation ablation guided by electroanatomical mapping has shown good efficacy. The increase in left atrium size was associated with atrial fibrillation recurrence.

Для цитирования: Kalil Carlos, Bartholomay Eduardo, Borges Anibal, Gazzoni Guilherme, Lima Edimar de, Etchepare Renata, Moraes Rafael, Sussenbach Carolina, Andrade Karina, Kalil Renato. Atrial fibrillation ablation by use of electroanatomical mapping: efficacy and recurrence factors.. Arquivos brasileiros de cardiologia. 2013. DOI: 10.5935/abc.20130211.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.