Catheter ablation of atrial fibrillation: Radiofrequency catheter ablation for redo procedures after cryoablation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kettering Klaus, Gramley Felix
Аннотация
AIM: To evaluate the effectiveness of two different strategies using radiofrequency catheter ablation for redo procedures after cryoablation of atrial fibrillation.
METHODS: Thirty patients (paroxysmal atrial fibrillation: 22 patients, persistent atrial fibrillation: 8 patients) had to undergo a redo procedure after initially successful circumferential pulmonary vein (PV) isolation with the cryoballoon technique (Arctic Front Balloon, CryoCath Technologies/Medtronic). The redo ablation procedures were performed using a segmental approach or a circumferential ablation strategy (CARTO; Biosense Webster) depending on the intra-procedural findings. After discharge, patients were scheduled for repeated visits at the arrhythmia clinic. A 7-day Holter monitoring was performed at 3, 12 and 24 mo after the ablation procedure.
RESULTS: During the redo procedure, a mean number of 2.9 re-conducting pulmonary veins (SD ± 1.0 PVs) were detected (using a circular mapping catheter). In 20 patients, a segmental approach was sufficient to eliminate the residual pulmonary vein conduction because there were only a few recovered pulmonary vein fibres. In the remaining 10 patients, a circumferential ablation strategy was used because of a complete recovery of the PV-LA conduction. All recovered pulmonary veins could be isolated successfully again. At 2-year follow-up, 73.3% of all patients were free from an arrhythmia recurrence (22/30). There were no major complications.
CONCLUSION: In patients with an initial circumferential pulmonary vein isolation using the cryoballoon technique, a repeat ablation procedure can be performed safely and effectively using radiofrequency catheter ablation.
METHODS: Thirty patients (paroxysmal atrial fibrillation: 22 patients, persistent atrial fibrillation: 8 patients) had to undergo a redo procedure after initially successful circumferential pulmonary vein (PV) isolation with the cryoballoon technique (Arctic Front Balloon, CryoCath Technologies/Medtronic). The redo ablation procedures were performed using a segmental approach or a circumferential ablation strategy (CARTO; Biosense Webster) depending on the intra-procedural findings. After discharge, patients were scheduled for repeated visits at the arrhythmia clinic. A 7-day Holter monitoring was performed at 3, 12 and 24 mo after the ablation procedure.
RESULTS: During the redo procedure, a mean number of 2.9 re-conducting pulmonary veins (SD ± 1.0 PVs) were detected (using a circular mapping catheter). In 20 patients, a segmental approach was sufficient to eliminate the residual pulmonary vein conduction because there were only a few recovered pulmonary vein fibres. In the remaining 10 patients, a circumferential ablation strategy was used because of a complete recovery of the PV-LA conduction. All recovered pulmonary veins could be isolated successfully again. At 2-year follow-up, 73.3% of all patients were free from an arrhythmia recurrence (22/30). There were no major complications.
CONCLUSION: In patients with an initial circumferential pulmonary vein isolation using the cryoballoon technique, a repeat ablation procedure can be performed safely and effectively using radiofrequency catheter ablation.