DOI 10.1016/j.avsg.2024.01.011
Digital Volumetric Measurements Based on 3D Scans of the Lower Limb: A Valid and Reproducible Method for Evaluation in Lymphedema Therapy.
Аннотация
BACKGROUND
Exact quantification of volumetric changes of the extremities is difficult and often error-prone. The aim of this study was to establish a standardized method based on 3-dimensional (3D) scans. Furthermore, this study tests the method in terms of reproducibility and evaluates volume changes after surgical therapy in patients suffering from lymphedema on the lower extremity.
METHODS
3D scans of the lower limb were performed with a mobile 3D scanner; "repeatability" and "interobserver reliability" of digital volumetry were tested. Furthermore, the method was applied on 31 patients suffering from chronic lymphedema.
RESULTS
Calculations of repeatability of the volume based on 20 3D scans of the same lower leg showed a mean volume of 2.488 ± 0.011 liters (range: 2.470-2.510). The mean volume of the different examiners did not differ significantly (F(2,18) = 1.579, P = 0.233). The paired t-test showed a significant mean volume decrease of 375 mL (95% confidence interval = 245/505 mL) between pretreatment and post-treatment (t (30) = 5.892, P < 0.001).
CONCLUSIONS
3D volumetry is a noninvasive, easy, and quick method to assess volume changes of the lower leg. Other than the low costs, it is reproducible and precise and therefore ideal for evolution of therapy in lymphedema.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.