Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2023
Small-volume tubes to reduce anemia and transfusion (STRATUS): a pilot study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Siegal Deborah M, Belley-Côté Emilie P, Lee Shun Fu, Robertson Tara, Hill Stephen, Benoit Pamela, Meeks Brandi, Owen Julian, Roglich Tanya, Zotova Elena, Connolly Stuart J
Аннотация
PURPOSE: Blood sampling for diagnostic testing causes blood loss. Small-volume tubes have the same cost, dimensions, and blood-draw techniques as standard-volume tubes, and are compatible with laboratory equipment; however, they are not commonly used. We sought to assess the feasibility of a stepped-wedge cluster trial to determine whether small-volume tubes reduce transfusion compared with standard-volume tubes in intensive care unit (ICU) patients.
METHODS: We conducted a prospective mixed-methods pilot study (before-after design) in one ICU with a six-week control period (standard-volume tubes) and a six-week intervention period (small-volume tubes). All patients admitted to the ICU were included. Feasibility was assessed as successful switch to small-volume tubes; adherence to tube size; sufficient volume for testing; user acceptance; barriers and facilitators to implementation; and 95% transfusion collection. We explored end-user acceptability using focus groups.
RESULTS: One hundred and sixty-five patients were included in the standard-volume and 204 in the small-volume periods. Transition to small-volume tubes was successful. Random audits showed 100% compliance. The proportion of samples with inadequate volume for testing was the same for both groups (both, 0.2%). Based on ten focus groups, small-volume tubes were acceptable with no barriers identified. Transfusion data collection was 100%. Median [interquartile range] estimated blood loss due to laboratory testing per patient per day in ICU was 11 [8-17] mL with standard-volume and 6 [4-8] mL with small-volume tubes.
CONCLUSION: Small-volume tubes can be implemented with acceptability to end-users and without barriers. They did not result in an increased frequency of inadequate samples. These results inform a trial to determine whether small-volume tubes reduce transfusion.
STUDY REGISTRATION: ClinicalTrials.gov (NCT03284944); registered 15 September 2017.
METHODS: We conducted a prospective mixed-methods pilot study (before-after design) in one ICU with a six-week control period (standard-volume tubes) and a six-week intervention period (small-volume tubes). All patients admitted to the ICU were included. Feasibility was assessed as successful switch to small-volume tubes; adherence to tube size; sufficient volume for testing; user acceptance; barriers and facilitators to implementation; and 95% transfusion collection. We explored end-user acceptability using focus groups.
RESULTS: One hundred and sixty-five patients were included in the standard-volume and 204 in the small-volume periods. Transition to small-volume tubes was successful. Random audits showed 100% compliance. The proportion of samples with inadequate volume for testing was the same for both groups (both, 0.2%). Based on ten focus groups, small-volume tubes were acceptable with no barriers identified. Transfusion data collection was 100%. Median [interquartile range] estimated blood loss due to laboratory testing per patient per day in ICU was 11 [8-17] mL with standard-volume and 6 [4-8] mL with small-volume tubes.
CONCLUSION: Small-volume tubes can be implemented with acceptability to end-users and without barriers. They did not result in an increased frequency of inadequate samples. These results inform a trial to determine whether small-volume tubes reduce transfusion.
STUDY REGISTRATION: ClinicalTrials.gov (NCT03284944); registered 15 September 2017.