DOI 10.1164/rccm.201002-0178oc
Elastic properties of the central airways in obstructive lung diseases measured using anatomical optical coherence tomography.
Аннотация
RATIONALE: Our understanding of how airway remodeling affects regional airway elastic properties is limited due to technical difficulties in quantitatively measuring dynamic, in vivo airway dimensions. Such knowledge could help elucidate mechanisms of excessive airway narrowing.
OBJECTIVES
To use anatomical optical coherence tomography (aOCT) to compare central airway elastic properties in control subjects and those with obstructive lung diseases.
METHODS
After bronchodilation, airway lumen area (Ai) was measured using aOCT during bronchoscopy in control subjects (n = 10) and those with asthma (n = 16), chronic obstructive pulmonary disease (COPD) (n = 9), and bronchiectasis (n = 8). Ai was measured in each of generations 0 to 5 while airway pressure was increased from -10 to 20 cm H(2)O. Airway compliance (Caw) and specific compliance (sCaw) were derived from the transpulmonary pressure (Pl) versus Ai curves.
MEASUREMENTS AND MAIN
RESULTS
Caw decreased progressively as airway generation increased, but sCaw did not differ appreciably across the generations. In subjects with asthma and bronchiectasis, Caw and sCaw were similar to control subjects and the Pl-Ai curves were left-shifted. No significant differences were observed between control and COPD groups.
CONCLUSIONS
Proximal airway elastic properties are altered in obstructive lung diseases. Although central airway compliance does not differ from control subjects in asthma, bronchiectasis, or COPD, Ai is lower in asthma and the Pl-Ai relationship is left-shifted in both asthma and bronchiectasis, suggesting that airways are maximally distended at lower inflating pressures. Such changes reflect alteration in the balance between airway wall distensibility and radial traction exerted on airways by surrounding lung parenchyma favoring airway narrowing. Clinical trial registered with Australian New Zealand Clinical Trials Registry (ACTRN12607000624482).
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.