MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jviromet.2023.114678

Медицинская библиотека · Journal of virological methods · 2023

A modified high-resolution melting-based assay (HRM) to identify the SARS-CoV-2 N501Y variant.

Aoki Akira, Adachi Hirokazu, Mori Yoko, Ito Miyabi, Sato Katsuhiko, Kinoshita Masayoshi, Kuriki Masahiro, Okuda Kenji, Sakakibara Toru, Okamoto Yoshinori, Jinno Hideto

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

High-resolution melting (HRM) analysis is a PCR-based method that can be used as a screening assay to identify SARS-CoV-2 variants. However, conventional HRM assays hardly detect slight melting temperature differences at the A-T to T-A transversion. As the N501Y substitution results from A-T to T-A transversion in A23063, few or no studies have shown that a conventional HRM assay can identify N501Y variants. This study successfully developed an HRM assay for identifying the N501Y mutation. Two HRM assays were used in the N501 site because the discrimination results were affected by the virus copy numbers. One is a conventional HRM assay (detectable at 103-106 copies/mL) and the other is a modified HRM assay by adding the wild-type fragment (detectable at 105-1010 copies/mL). Using viral RNAs from cultured variants (Alpha, Beta, and Gamma), a modified HRM assay correctly identified three N501Y variants because of high-copy-number RNAs in those viral samples. The sensitivity and specificity of the N501Y assay were 93.3% and 100%, respectively, based on 209 clinical samples (105 for N501; 104 for N501Y). These results suggest that our HRM-based assay is a powerful tool for rapidly identifying various SARS-CoV-2 variants.

Для цитирования: Aoki Akira, Adachi Hirokazu, Mori Yoko, Ito Miyabi, Sato Katsuhiko, Kinoshita Masayoshi, Kuriki Masahiro, Okuda Kenji, Sakakibara Toru, Okamoto Yoshinori, Jinno Hideto. A modified high-resolution melting-based assay (HRM) to identify the SARS-CoV-2 N501Y variant.. Journal of virological methods. 2023. DOI: 10.1016/j.jviromet.2023.114678.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.