MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0b013e31820f1585

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2011

Illumination system for corneal collagen crosslinking.

Sheehan Matthew, Watson Bill, Goncharov Alexander

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: We have designed and constructed an ultraviolet (UV) illumination system for use in corneal collagen crosslinking (CXL) procedures. CXL is a recently developed procedure to treat Keratectasia such as Keratoconus and Pellucid Marginal Degeneration. The role of the illumination system is to safely provide UV light at the absorption peak of the Riboflavin photosensitizer, which generates reactive oxygen species and subsequently increases the number of covalent bonds between collagen fibrils.

METHODS

Raytracing simulations were used to compare various optical designs for the illumination system. Alternative layouts are presented and design compromises between competing goals are discussed in reference to safety and practical considerations for clinical use. The mechanical mounting system and the beam output power and beam diameter testing system are briefly described.

RESULTS

The illumination system has several features that help provide uniform effectivity of the applied treatment over the desired treatment diameter, assuming Riboflavin has uniform absorption in the treatment zone. The optical design offers substantially greater beam control and safety than rudimentary devices relying on direct illumination. The prototype was relatively inexpensive to construct and includes a mounting system and beam testing setup.

CONCLUSIONS

The UV illumination system was found to be successful in providing a balanced solution regarding clinical use and the eye safety issues relevant to CXL.

Для цитирования: Sheehan Matthew, Watson Bill, Goncharov Alexander. Illumination system for corneal collagen crosslinking.. Optometry and vision science : official publication of the American Academy of Optometry. 2011. DOI: 10.1097/opx.0b013e31820f1585.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.