MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0b013e3181fb4fa7

Медицинская библиотека · Cornea · 2011

Corneal elevation topography: best fit sphere, elevation distance, asphericity, toricity, and clinical implications.

Gatinel Damien, Malet Jacques, Hoang-Xuan Thanh, Azar Dimitri T

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To describe the effect of the corneal asphericity and toricity on the map patterns and best fit sphere (BFS) characteristics in elevation topography.

METHODS

The corneal surface was modeled as a biconic surface of principal radii and asphericity values of r1 and r2 and Q1 and Q2, respectively. The apex of the biconic surface corresponded to the origin of a polar coordinates system. Minimization of the squared residuals was used to calculate the values of the radii of the BFSs and apex distance (A-values: z distance between the corneal apex and the BFS) of the modeled corneal surface for various configurations relating to commonly clinically measured values of apical radius, asphericity, and toricity.

RESULTS

Increased apical radius of curvature and increased prolateness (negative asphericity) led to an increase in BFS radius but had opposite effects on the A-value. Increased prolateness resulted in increased BFS radius and A-value. Increasing toricity did not alter these findings. Color-plot elevation maps of the modeled corneal surface showed complete ridge patterns when toricity was increased and showed incomplete ridge and island patterns when prolateness was increased.

CONCLUSIONS

High A-values in patients with corneal astigmatism may result from steep apical curvature and/or high prolateness (negative asphericity). The BFS radius may help in distinguishing between these 2 causes of increased A-values. Increased prolateness and decreased apical radius of curvature (often seen in keratoconus) have opposite effects on the BFS radius but similar effects on the apex distance.

Для цитирования: Gatinel Damien, Malet Jacques, Hoang-Xuan Thanh, Azar Dimitri T. Corneal elevation topography: best fit sphere, elevation distance, asphericity, toricity, and clinical implications.. Cornea. 2011. DOI: 10.1097/ico.0b013e3181fb4fa7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.