MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0b013e3181e2cf57

Медицинская библиотека · Cornea · 2011

Intrastromal corneal ring segment implantation for the treatment of keratoconus.

Kubaloglu Anl, Sari Esin Sogutlu, Cinar Yasin, Koytak Arif, Kurnaz Ekrem, Ozertürk Yusuf

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the safety and efficacy of intrastromal corneal ring segment implantation using both mechanical and femtosecond-assisted tunnel creation for the treatment of patients with keratoconus.

METHODS

A retrospective noncomparative interventional study including 96 eyes of 75 patients with keratoconus. All patients had contact lens intolerance and clear central corneas. Corneal tunnels were made using a femtosecond laser in 26 eyes (femtosecond group) and mechanically in 70 eyes (mechanical group). The Keraring (Mediphacos, Belo Horizonte, Brazil) was implanted in each eye, and a complete ophthalmic examination was performed, including visual acuity, refraction, and keratometric readings.

RESULTS

The mean preoperative uncorrected visual acuity for all eyes was 1.40 ± 0.39 logarithm of the minimal angle of resolution (logMAR) (mean ± SD) and improved to 0.60 ± 0.34 logMAR at the sixth month (n = 96, P < 0.001) and 0.50 ± 0.32 (n = 54, P < 0.001) at the 18th month. The mean preoperative best spectacle-corrected visual acuity (BSCVA) for all eyes (n = 96) was 0.68 ± 0.36 logMAR. The mean BSCVA was 0.29 ± 0.21 (n = 96, P < 0.001) at the sixth month and improved to 0.26 ± 0.20 (n = 54, P < 0.001) at the 18th month. There was a significant reduction in spherical equivalent refractive error from -5.88 ± 3.65 diopters (D) (n = 96) to -2.26 ± 1.98 D (n = 54, P < 0.001) at the 18th month. The mean preoperative maximum keratometry (Kmax) was 53.58 ± 5.90 D and decreased to 49.02 ± 4.70 (n = 96, P < 0.001) at 6 months and 48.57 ± 4.36 D (n = 54, P < 0.001) at the 18th month. Sixth month results of the mechanical versus femtosecond groups were as follows: improvement in uncorrected visual acuity (2.08 vs. 1.50 lines), improvement in BSCVA (2.93 vs. 2.19), reduction in spherical equivalent (3.78 vs. 3.75 D), and reduction in maximum keratometry (4.66 vs. 4.62 D). There was no statistically significant difference between both groups for any parameter.

CONCLUSIONS

Keraring implantation is effective for the treatment of keratoconus, providing safety and good visual outcomes after both mechanical and femtosecond-assisted tunnel creation.

Для цитирования: Kubaloglu Anl, Sari Esin Sogutlu, Cinar Yasin, Koytak Arif, Kurnaz Ekrem, Ozertürk Yusuf. Intrastromal corneal ring segment implantation for the treatment of keratoconus.. Cornea. 2011. DOI: 10.1097/ico.0b013e3181e2cf57.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.