Медицинская библиотека · Cornea · 2010

Changes in corneal biomechanics in patients with keratoconus after penetrating keratoplasty.

Yenerel Nursal Melda, Kucumen Raciha Beril, Gorgun Ebru

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To examine the biomechanical properties of keratoconic eyes following penetrating keratoplasty and to compare results with the biomechanical characteristics of manifest keratoconus, forme fruste keratoconus and normal eyes as measured with the Reichert ocular response analyzer (ORA).

METHODS

This retrospective analysis comprised a total of 169 eyes: 34 eyes with forme fruste keratoconus (group FF), 36 eyes with manifest keratoconus (Group KC), 36 eyes that have undergone penetrating keratoplasty (Group PK) and a control group of 63 normal eyes (Group N). Corneal hysteresis (CH), corneal resistance factor (CRF), corneal compensated intraocular pressure, and Goldmann correlated intraocular pressure were measured by ORA. Central corneal thickness was calculated by the integrated handheld ultrasonic pachymeter of the ORA. The statistical analysis focused on CH and CRF changes among the 4 groups.

RESULTS

When compared with normal eyes, mean CH and CRF values were found significantly lower in all groups (P < 0.05). Mean CH values were 8.19 ± 1.49 mm Hg in Group KC, 9.21 ± 1.38 mm Hg in Group FF, 10.16 ± 1.93 mm Hg in Group PK, and 11.43 ± 1.52 mm Hg in normal eyes (Group N). Although there was not a significant difference in mean CH values between Groups PK and FF (P = 0.072), the difference was significant between Groups KC as well as FF and Groups KC and PK (P < 0.05). Mean CRF values were found as 6.79 ± 1.81 mm Hg (Group KC), 8.21 ± 1.64 mm Hg (Group FF), 9.94 ± 2.34 mm Hg (Group PK), and 11.53 ± 1.83 mm Hg in Group N. The difference was statistically significant among all groups (P < 0.05).

CONCLUSIONS

Penetrating keratoplasty has a beneficial effect on corneal biomechanics in keratoconic eyes. CH and CRF parameters approach the range of normal eyes after corneal transplantation.

Для цитирования: Yenerel Nursal Melda, Kucumen Raciha Beril, Gorgun Ebru. Changes in corneal biomechanics in patients with keratoconus after penetrating keratoplasty.. Cornea. 2010. DOI: 10.1097/ico.0b013e3181ca6383.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.