DOI 10.1016/j.jcrs.2010.04.028
Comparison of mechanical and femtosecond laser tunnel creation for intrastromal corneal ring segment implantation in keratoconus: prospective randomized clinical trial.
Аннотация
PURPOSE: To compare the outcomes of mechanical and femtosecond laser-assisted tunnel creation for intrastromal corneal ring segment (ICRS) implantation in eyes with keratoconus.
SETTING
Kartal Training and Research Hospital, Istanbul, Turkey.
METHODS
In this prospective study, consecutive eyes with keratoconus were randomly assigned to have ICRS tunnel creation with a mechanical device or a femtosecond laser. Keraring ICRS with a 5.0 mm diameter and 160-degree arc length were implanted in all cases. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, and keratometry (K) readings were measured preoperatively and 1 year postoperatively, and the data in the mechanical group and the femtosecond group were compared statistically.
RESULTS
One year postoperatively, there was significant improvement in UDVA, CDVA, K readings, spherical equivalent (SE), and manifest sphere and cylinder in both groups (P<.05). The UDVA improved by 2.4 lines in the mechanical group and 2.0 lines in the femtosecond group and the CDVA by 3.3 lines and 2.7 lines, respectively; the mean reduction in maximum keratometry was 4.50 diopters (D) and 4.70 D, respectively, and the mean reduction in SE, 3.18 D and 3.09 D, respectively. There were no statistically significant differences between the 2 groups in visual or refractive results (P>.05). Anterior corneal perforation, superficial segment placement, and segment extrusion occurred in 1 eye each in the mechanical group. Segment migration occurred in 1 eye in the femtosecond group.
CONCLUSION
Despite intraoperative complications in the mechanical group, the visual and refractive outcomes were similar to those in the femtosecond group.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.