MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2010.04.028

Медицинская библиотека · Journal of cataract and refractive surgery · 2010

Comparison of mechanical and femtosecond laser tunnel creation for intrastromal corneal ring segment implantation in keratoconus: prospective randomized clinical trial.

Kubaloglu Anil, Sari Esin Sogutlu, Cinar Yasin, Cingu Kürşat, Koytak Arif, Coşkun Erol, Ozertürk Yusuf

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the outcomes of mechanical and femtosecond laser-assisted tunnel creation for intrastromal corneal ring segment (ICRS) implantation in eyes with keratoconus.

SETTING

Kartal Training and Research Hospital, Istanbul, Turkey.

METHODS

In this prospective study, consecutive eyes with keratoconus were randomly assigned to have ICRS tunnel creation with a mechanical device or a femtosecond laser. Keraring ICRS with a 5.0 mm diameter and 160-degree arc length were implanted in all cases. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, and keratometry (K) readings were measured preoperatively and 1 year postoperatively, and the data in the mechanical group and the femtosecond group were compared statistically.

RESULTS

One year postoperatively, there was significant improvement in UDVA, CDVA, K readings, spherical equivalent (SE), and manifest sphere and cylinder in both groups (P<.05). The UDVA improved by 2.4 lines in the mechanical group and 2.0 lines in the femtosecond group and the CDVA by 3.3 lines and 2.7 lines, respectively; the mean reduction in maximum keratometry was 4.50 diopters (D) and 4.70 D, respectively, and the mean reduction in SE, 3.18 D and 3.09 D, respectively. There were no statistically significant differences between the 2 groups in visual or refractive results (P>.05). Anterior corneal perforation, superficial segment placement, and segment extrusion occurred in 1 eye each in the mechanical group. Segment migration occurred in 1 eye in the femtosecond group.

CONCLUSION

Despite intraoperative complications in the mechanical group, the visual and refractive outcomes were similar to those in the femtosecond group.

Для цитирования: Kubaloglu Anil, Sari Esin Sogutlu, Cinar Yasin, Cingu Kürşat, Koytak Arif, Coşkun Erol, Ozertürk Yusuf. Comparison of mechanical and femtosecond laser tunnel creation for intrastromal corneal ring segment implantation in keratoconus: prospective randomized clinical trial.. Journal of cataract and refractive surgery. 2010. DOI: 10.1016/j.jcrs.2010.04.028.