Corneal biomechanical metrics and anterior segment parameters in mild keratoconus.

Fontes Bruno M, Ambrósio Renato, Jardim Daniela, Velarde Guillermo C, Nosé Walton

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare corneal hysteresis (CH), corneal resistance factor (CRF), spherical equivalent (SE), average central keratometry (K-Avg), corneal astigmatism (CA), corneal volume (CV), anterior chamber (AC) depth, and central corneal thickness (CCT) between patients with mild keratoconus and healthy controls and to estimate the sensitivity and specificity of CH and CRF in discriminating mild keratoconus from healthy corneas.

DESIGN

Comparative case series.

PARTICIPANTS

Sixty-three eyes (40 patients) with mild keratoconus (group 1) and 80 eyes from 40 gender- and age-matched controls (group 2).

METHODS

Patients underwent a complete clinical eye examination, corneal topography (Humphrey ATLAS; Carl Zeiss Meditec, Dublin, CA), tomography (Pentacam; Oculus, Wetzlar, Germany), and biomechanical evaluations (ocular response analyzer; Reichert Ophthalmic Instruments, Depew, NY). The receiver operating characteristic (ROC) curve was used to identify cutoff points that maximized sensitivity and specificity in discriminating mild keratoconus from normal corneas.

MAIN OUTCOME MEASURES: Corneal hysteresis, CRF, SE, K-Avg, CA, CV, AC depth, and CCT. The diagnostic performance of CH and CRF for detecting mild keratoconus was assessed using the ROC curve.

RESULTS

In group 1 versus group 2, the SE values (mean+/-standard deviation) were -3.55+/-2.87 diopters (D) versus -1.46+/-3.09 D (P = 0); K-Avg, 45.09+/-2.24 versus 43.24+/-1.54 D (P = 0); CA, 3.15+/-1.87 versus 1.07+/-0.83 D (P = 0); CV, 57.3+/-2.12 versus 60.86+/-3.39 mm3 (P = 0); AC depth, 3.19+/-0.35 versus 3.05+/-0.43 mm (P = 0.0416); CCT, 503+/-34.15 versus 544.71+/-35.89 microm (P = 0); CH, 8.50+/-1.36 versus 10.17+/-1.79 mmHg (P = 0); CRF, 7.85+/-1.49 versus 10.13+/-2.0 mmHg (P = 0). The ROC curve analyses showed a poor overall predictive accuracy of CH (cutoff, 9.64 mmHg; sensitivity, 87%; specificity, 65%; test accuracy, 74.83%) and CRF (cutoff, 9.60 mmHg; sensitivity, 90.5%; specificity, 66%; test accuracy, 76.97%) for detecting mild keratoconus.

CONCLUSIONS

The values for CH, CRF, CV, and CCT were statistically lower and those for SE, K-Avg, CA, and AC depth were statistically higher in patients with mild keratoconus compared with controls. Corneal hysteresis and CRF were poor parameters for discriminating between mild keratoconus and normal corneas.

FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.

Для цитирования: Fontes Bruno M, Ambrósio Renato, Jardim Daniela, Velarde Guillermo C, Nosé Walton. Corneal biomechanical metrics and anterior segment parameters in mild keratoconus.. Ophthalmology. 2010. DOI: 10.1016/j.ophtha.2009.09.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.