Keratoconus and normal-tension glaucoma: a study of the possible association with abnormal biomechanical properties as measured by corneal hysteresis (An AOS Thesis).

Cohen Elisabeth J

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To test the hypothesis that keratoconus and pellucid patients who have glaucoma or are suspected of having glaucoma have lower corneal hysteresis (CH) and/or corneal resistance factor (CRF) measurements compared to controls.

METHODS

A prospective study at a tertiary eye center of keratoconus and pellucid patients with glaucoma or suspected of having glaucoma, and age-matched keratoconus and pellucid controls, was performed. After informed consent was obtained, corneal topography, ocular response analyzer measurements, pachymetry, intraocular pressure, A-scan measurements, Humphrey visual fields (VFs), and disc photos were done. Analyses compared cases to controls on primary (CH and CRF) and secondary variables. Disc photos and VFs were rated in a masked fashion.

RESULTS

The mean CH (8.2, SD=1.6, vs 8.3, SD=1.5) and CRF (7.3, SD=2.0, vs 6.9, SD=2.1) were low and did not differ significantly between 20 study patients (29 eyes) and 40 control patients (61 eyes), respectively. CH had a negative, significant correlation with maximum corneal curvature by topography (P < .002) and positive, significant correlation with central corneal thickness (P < .003). The mean cup-disc ratio was larger among cases than controls (0.54, SD=0.20, vs 0.38, SD=0.20; P = .003). VFs were suggestive of glaucoma more often among the study eyes than controls (11 of 29, 37.9%, vs 8 of 60, 13.3%; P =.019).

CONCLUSIONS

CH was low in study and control patients and was correlated with severity of keratoconus/pellucid, but not with glaucoma/suspected glaucoma or control status. Evidence of glaucoma was more common in study eyes than controls, but was present in both.

Для цитирования: Cohen Elisabeth J. Keratoconus and normal-tension glaucoma: a study of the possible association with abnormal biomechanical properties as measured by corneal hysteresis (An AOS Thesis).. Transactions of the American Ophthalmological Society. 2009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.