Safety and applicability of a pre-stage public access ventilator for trained laypersons: a proof of principle study.

Fuchs Patricia, Obermeier Juliane, Kamysek Svend, Degner Martin, Nierath Hannes, Jürß Henning, Ewald Hartmut, Schwarz Jens, Becker Martin, Schubert Jochen K

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Contemporary resuscitation guidelines for basic life support recommend an immediate onset of cardiac compressions in case of cardiac arrest followed by rescue breaths. Effective ventilation is often omitted due to fear of doing harm and fear of infectious diseases. In order to improve ventilation a pre-stage of an automatic respirator was developed for use by laypersons.

METHODS

Fifty-two healthy volunteers were ventilated by means of a prototype respirator via a full-face mask in a pilot study. The pre-stage public access ventilator (PAV) consisted of a low-cost self-designed turbine, with sensors for differential pressure, flow, FO2, FCO2 and 3-axis acceleration measurement. Sensor outputs were used to control the respirator and to recognize conditions relevant for efficiency of ventilation and patients' safety. Different respiratory manoeuvres were applied: a) pressure controlled ventilation (PCV), b) PCV with controlled leakage and c) PCV with simulated airway occlusion. Sensor signals were analysed to detect leakage and airway occlusion. Detection based upon sensor signals was compared with evaluation based on clinical observation and additional parameters such as exhaled CO2.

RESULTS

Pressure controlled ventilation could be realized in all volunteers. Leakage was recognized with 93.5% sensitivity and 93.5% specificity. Simulated airway occlusion was detected with 91.8% sensitivity and 91.7% specificity.

CONCLUSION

The pre-stage PAV was able to detect potential complications relevant for patients' safety such as leakage and airway occlusion in a proof of principle study. Prospectively, this device provides a respectable basis for the development of an automatic emergency respirator and may help to improve bystander resuscitation.

Для цитирования: Fuchs Patricia, Obermeier Juliane, Kamysek Svend, Degner Martin, Nierath Hannes, Jürß Henning, Ewald Hartmut, Schwarz Jens, Becker Martin, Schubert Jochen K. Safety and applicability of a pre-stage public access ventilator for trained laypersons: a proof of principle study.. BMC emergency medicine. 2017. DOI: 10.1186/s12873-017-0150-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.