MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-026-12372-3

Медицинская библиотека · European radiology · 2026

Feasibility of BMI-based sub-milliSievert low-dose CT in individualized detection of lung nodules.

Qu Siqi, Chen Qiuxing, Li Shulin, Han Qijia, Ai Zhu, Wu Minyi, Ma Kun, Xiang Zhiming

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate the performance of a body mass index (BMI)-based sub-milliSievert low-dose CT (LDCT) protocol with multiple reconstruction algorithms for image quality and lung nodule assessment.

MATERIALS AND

METHODS

This prospective study included 214 participants who underwent standard-dose CT (SDCT, 3.68 ± 1.53 mSv) reconstructed with 50% adaptive statistical iterative reconstruction (ASIR-V-50%) and LDCT. LDCT was randomly divided into a higher-dose group (LD-A, 0.57-1.15 mSv, n = 108) and a lower-dose group (LD-B, 0.33-0.63 mSv, n = 106). Each group was stratified into four BMI-based subgroups with individualized protocols reconstructed with deep learning image reconstruction (DLIR-H and DLIR-M), ASIR-V-50%, and filtered back projection (FBP). Image quality, nodule detection across BMI subgroups, and the performance of four algorithms in detection, size measurement accuracy, and Lung-RADS v2022 consistency were analyzed.

RESULTS

In LDCT, DLIR-H provided superior image quality (p < 0.001) and the highest overall nodule detection rate (99.04%), surpassing ASIR-V-50% (98.55%) and FBP (97.87%) (both p < 0.05). The advantage was most evident for nodules < 6 mm, while all nodules ≥ 6 mm were consistently detected across algorithms. Detection rates showed no significant variation among BMI subgroups (all p > 0.05). For measurement accuracy, FBP and ASIR-V-50% performed better in LD-A (all p < 0.05), whereas DLIR-M was superior in LD-B (p < 0.001). All algorithms demonstrated excellent Lung-RADS agreement (κ > 0.9, p < 0.001).

CONCLUSION

A BMI-based sub-milliSievert LDCT protocol significantly reduced radiation exposure while maintaining nodule detection across BMI subgroups, with DLIR offering superior image quality and diagnostic performance.

KEY POINTS: Question Evidence remains scarce on BMI-based sub-milliSievert low-dose CT using different reconstruction algorithms, regarding image quality and nodules detection (particularly < 6 mm). Findings BMI-based sub-milliSievert low-dose CT ensured balanced detectability across populations, while deep learning reconstruction improved image quality and achieved excellent sensitivity for lung nodule detection. Clinical relevance Deep learning reconstruction enhanced BMI-based sub-milliSievert low-dose CT, supporting its application in personalized sub-milliSievert low-dose lung cancer screening.

Для цитирования: Qu Siqi, Chen Qiuxing, Li Shulin, Han Qijia, Ai Zhu, Wu Minyi, Ma Kun, Xiang Zhiming. Feasibility of BMI-based sub-milliSievert low-dose CT in individualized detection of lung nodules.. European radiology. 2026. DOI: 10.1007/s00330-026-12372-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.