MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-023-01577-x

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2023

Characteristics of the phenotype of mixed cardiomyopathy in patients with implantable cardioverter-defibrillators.

Raja Deep Chandh, Samarawickrema Indira, Menon Sarat Krishna, Singh Rikvin, Mehta Abhinav, Tuan Lukah Q, Pandurangi Ulhas, Jain Sanjiv, Callans David J, Marchlinski Francis E, Abhayaratna Walter P, Sanders Prashanthan, Pathak Rajeev K

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND OR PURPOSE: The prognosis of m ixed cardiomyopathy (CMP) in patients with implanted cardioverter-defibrillators (ICDs) has not been investigated. We aim to study the demographic, clinical, device therapies and survival characteristics of mixed CMP in a cohort of patients implanted with a defibrillator.

METHODS

The term mixed CMP was used to categorise patients with impaired left ventricular ejection fraction attributed to documented non-ischemic triggers with concomitant moderate coronary artery disease. This is a single center observational cohort of 526 patients with a mean follow-up of 8.7 ± 3.5 years.

RESULTS

There were 42.5% patients with ischemic cardiomyopathy (ICM), 26.9% with non-ischemic cardiomyopathy (NICM) and 30.6% with mixed CMP. Mixed CMP, compared to NICM, was associated with higher mean age (69.1 ± 9.6 years), atrial fibrillation (55.3%) and greater incidence of comorbidities. The proportion of patients with mixed CMP receiving device shocks was 23.6%, compared to 18.4% in NICM and 27% in ICM. The VT cycle length recorded in mixed CMP (281.6 ± 43.1 ms) was comparable with ICM (282.5 ± 44 ms; p = 0.9) and lesser than NICM (297.7 ± 48.7 ms; p = 0.1). All-cause mortality in mixed CMP (21.1%) was similar to ICM (20.1%; p = 0.8) and higher than NICM (15.6%; p = 0.2). The Kaplan-Meier curves revealed hazards of 1.57 (95% CI: 0.91, 2.68) for mixed CMP compared to NICM.

CONCLUSION

In a cohort of patients with ICD, the group with mixed CMP represents a phenotype predominantly comprised of the elderly with a higher incidence of comorbidities. Mixed CMP resembles ICM in terms of number of device shocks and VT cycle length. Trends of long-term prognosis of patients with mixed CMP are worse than NICM and similar to ICM.

Для цитирования: Raja Deep Chandh, Samarawickrema Indira, Menon Sarat Krishna, Singh Rikvin, Mehta Abhinav, Tuan Lukah Q, Pandurangi Ulhas, Jain Sanjiv, Callans David J, Marchlinski Francis E, Abhayaratna Walter P, Sanders Prashanthan, Pathak Rajeev K. Characteristics of the phenotype of mixed cardiomyopathy in patients with implantable cardioverter-defibrillators.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2023. DOI: 10.1007/s10840-023-01577-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.