Breeman K T N, Peijster A J L, De Bruin-Bon H A C M, Pepplinkhuizen S, Van der Stuijt W, De Veld J A, Beurskens N E G, Stuiver M M, Wilde A A M, Tjong F V Y, Knops R E

Аннотация

BACKGROUND: Transvenous implantable cardioverter-defibrillators (TV-ICDs) are associated with greater tricuspid regurgitation (TR) severity, which leads to increased mortality. The pathophysiology is assumed to be lead-related, hence, treatment includes lead extraction. However, TR may also naturally occur in the high-risk ICD population, or may be caused by right ventricular pacing. We sought to evaluate the effect of ICD type (with or without lead) and pacing percentage on post-implantation TR severity.

METHODS: In this retrospective cohort study, consecutive patients were included with a primary S-ICD or TV-ICD implantation between 2009 and 2019 and echocardiography studies ≤3 months before and ≤ 3 years post-implantation. The effect of ICD type on TR severity at follow-up was estimated adjusting for ventricular pacing percentage and potential confounders. The effect of ventricular pacing percentage on TR severity at follow-up was adjusted for potential confounders.

RESULTS: 118 patients were included (mean age 52 ± 21): 31 (26%) with an S-ICD and 87 (74%) with a TV-ICD. Median 20 months post-implantation, worsening TR was found in 11/31 (34%) S-ICD patients and 45/87 (52%) TV-ICD patients (p = 0.15). Adjusted for age, atrial fibrillation, baseline TR and mitral regurgitation, ventricular pacing percentage, ICD dwelling time, BMI, hypertension and left ventricular ejection fraction, TV-ICDs were significantly associated with greater TR severity (OR 9.90, p = 0.002). Ventricular pacing percentage was very low, and not significantly associated with greater TR severity (OR 0.95, p = 0.066).

CONCLUSIONS: Our results suggest that greater TR severity in ICD patients is mainly caused by the transvenous lead, rather than natural progression in the ICD population.