MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mnm.0000000000002116

Медицинская библиотека · Nuclear medicine communications · 2026

Multicentre survey of diagnostic reference levels for single-photon emission computed tomography/computed tomography and PET/computed tomography examinations at Japanese National University Hospitals: a comparative international analysis.

Iimori Takashi, Kamiya Takashi, Maeda Yukito, Odagiri Hayato, Iguchi Harumi, Yada Nobuhiro, Narita Masataka

СтатьяСравнительное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

Diagnostic reference levels (DRLs) are essential indicators for optimising medical radiation exposure, although implementation varies by country. In Japan, the Association of Radiological Technologists in National University Hospitals (ARTNU) investigated baseline DRLs for nuclear medicine based on a nationwide survey, referring to Japan DRLs 2020. These include the 50 th and 75 th percentile values, providing practical benchmarks for administered activity management. However, comparative insights with Japan DRLs 2025 and international standards remain limited.

METHODS

This nationwide survey, conducted across 42 Japanese national university hospitals, examined radiopharmaceutical and computed tomography (CT) dose indices in single-photon emission computed tomography/CT (SPECT/CT) and positron emission tomography/CT (PET/CT) examinations and compared the results with Japan DRLs 2020; Japan DRLs 2025; and international benchmarks from the UK, Europe, USA, Korea, Australia, and Thailand. Japan DRLs 2025 introduced procedural refinements and anatomy-based CT classifications, particularly for PET/CT, aligning with evolving clinical protocols.

RESULTS

Data on radiopharmaceutical administered activities and CT parameters (CT dose index volume, dose length product) were collected. 18 F-fluorodeoxyglucose-PET protocols predominantly applied 4.0 MBq/kg weight-based dosing, whereas SPECT/CT uses fixed radiopharmaceutical administered activities. CT dose was adapted according to imaging purpose and anatomical region, frequently achieving low-dose operation. Although ARTNU DRLs 2020 remained clinically useful, they exhibited broader administered activity distributions and lack anatomical specificity.

CONCLUSION

ARTNU DRLs 2020 should be revised with a follow-up survey to better reflect current practices and align with the increased granularity of Japan DRLs 2025. Japanese institutions have demonstrated concordance with global standards and ongoing optimisation of radiopharmaceutical administered activity and CT dose indices through technological advancements.

Для цитирования: Iimori Takashi, Kamiya Takashi, Maeda Yukito, Odagiri Hayato, Iguchi Harumi, Yada Nobuhiro, Narita Masataka. Multicentre survey of diagnostic reference levels for single-photon emission computed tomography/computed tomography and PET/computed tomography examinations at Japanese National University Hospitals: a comparative international analysis.. Nuclear medicine communications. 2026. DOI: 10.1097/mnm.0000000000002116.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.