Using artificial intelligence for automated assessment of point-of-care ultrasound (POCUS) skills in emergency medicine.

Duggan Nicole M, Dias Roger D, Harari Rayan, Borges Paulo, Verly Robson J, Schwid Madeline, Fischetti Chanel E, Allan-Blitz Lao-Tzu, Heron Daniel, Huang Calvin K, Goldsmith Andrew J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

This study aimed to demonstrate the feasibility of using computer vision (CV) to unobtrusively extract body motion metrics from videos of emergency medicine (EM) clinicians, and gather validity evidence of these metrics to differentiate POCUS skills between novice and experts, as well as to capture skills gained over time.

METHODS

Prospective cohort study including novice and expert EM clinicians performing echocardiogram (ECHO) and focused assessment with sonography for trauma (FAST) exams on a live simulated patient. Expert observers provided objective structured clinical examination (OSCE) scores (numerical ratings on a scale from 1 to 100), and sonographers' hands and head motion metrics (path length, speed, acceleration, jerk, and smoothness) were extracted via CV using 2-dimensional videos. Data points were captured at baseline, and for novices at baseline and after 12-15 months of residency training.

RESULTS

CV achieved high detection rates (99.52% ECHO, 98.70% FAST). At baseline, experts demonstrated superior OSCE scores (ECHO: 98.6 ± 2.1 vs 63.4 ± 17.0; FAST: 99.2 ± 1.5 vs 68.9 ± 17.7, p < 0.001) and faster task completion (101.8 ± 44.7 vs 240.3 ± 84.1 s, p < 0.001). Experts exhibited smoother hand movements (left hand smoothness: -129.3 ± 47.6 vs -241.3 ± 64.6, p < 0.001) and reduced total path lengths. After 12-15 months of training, novices showed significant improvements in OSCE scores (ECHO: 85.3 ± 10.3; FAST: 84.8 ± 6.5) and task efficiency (134.0 ± 35.6 s), with improvements in motion smoothness and reduced path lengths (p < 0.001). Motion metrics strongly correlated with OSCE scores (r = 0.455-0.783) and task completion time (r = 0.491-0.951).

CONCLUSIONS

CV successfully extracted objective motion metrics that differentiated POCUS skill levels between novices and experts and captured skill development over time. This approach offers a scalable, unobtrusive method for objective POCUS assessment, while supporting competency-based medical education frameworks.

Для цитирования: Duggan Nicole M, Dias Roger D, Harari Rayan, Borges Paulo, Verly Robson J, Schwid Madeline, Fischetti Chanel E, Allan-Blitz Lao-Tzu, Heron Daniel, Huang Calvin K, Goldsmith Andrew J. Using artificial intelligence for automated assessment of point-of-care ultrasound (POCUS) skills in emergency medicine.. The American journal of emergency medicine. 2026. DOI: 10.1016/j.ajem.2026.01.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.