European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology · 2011
Comparison of mitral valve area by pressure half-time and proximal isovelocity surface area method in patients with mitral stenosis: effect of net atrioventricular compliance.
Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Salem Omar Alaa Mabrouk, Tanaka Hidekazu, AbdelDayem Tarek Khairy, Sadek Ayman S, Raslaan Halah, Al-Sherbiny Ashraf, Yamawaki Kohei, Ryo Keiko, Fukuda Yuko, Norisada Kazuko, Tatsumi Kazuhiro, Onishi Tetsuari, Matsumoto Kensuke, Kawai Hiroya, Hirata Ken-ichi
Аннотация
AIMS: The aim of this study was to test the hypothesis that, unlike calculation of the mitral valve area (MVA) with the pressure half-time method (PHT), the proximal isovelocity surface area method (PISA) is not affected by changes in net atrioventricular compliance (C(n)).
METHODS AND RESULTS: We studied 51 patients with mitral stenosis (MS) from two centres. MVA was assessed with the PISA (MVA(PISA)), PHT (MVA(PHT)), and planimetry (MVA(PLN), serving as the gold standard) method. C(n) was calculated with a previously validated equation using 2D echocardiography. MVA(PISA) closely correlated with MVA(PLN) (r = 0.96, P < 0.0001), while MVA(PHT) and MVA(PLN) showed a weaker but still good correlation (r = 0.69, P < 0.0001). The correlation between MVA(PHT) and MVA(PLN) for patients with C(n) between 4 and 6 mL/mmHg (considered to be normal) was excellent (r = 0.93, P < 0.0001), but that for patients with C(n) of less than 4 or more than 6 mL/mmHg was not as good (r = 0.64, P < 0.0001). Importantly, a significant inverse correlation was detected between the percentage difference among MVA(PHT), MVA(PLN), and C(n) (r = -0.77, P < 0.0001), but the line of fit was nearly flat for the percentage difference among MVA(PISA), MVA(PLN), and C(n) (r = 0.1, P = 0.388).
CONCLUSION: MVA calculated with both the PISA and PHT methods correlated well with MVA calculated with the planimetry method. However, the PISA rather than PHT is recommended for patients with MS and extreme C(n) values because PISA, unlike PHT, is not affected by changes in C(n).
METHODS AND RESULTS: We studied 51 patients with mitral stenosis (MS) from two centres. MVA was assessed with the PISA (MVA(PISA)), PHT (MVA(PHT)), and planimetry (MVA(PLN), serving as the gold standard) method. C(n) was calculated with a previously validated equation using 2D echocardiography. MVA(PISA) closely correlated with MVA(PLN) (r = 0.96, P < 0.0001), while MVA(PHT) and MVA(PLN) showed a weaker but still good correlation (r = 0.69, P < 0.0001). The correlation between MVA(PHT) and MVA(PLN) for patients with C(n) between 4 and 6 mL/mmHg (considered to be normal) was excellent (r = 0.93, P < 0.0001), but that for patients with C(n) of less than 4 or more than 6 mL/mmHg was not as good (r = 0.64, P < 0.0001). Importantly, a significant inverse correlation was detected between the percentage difference among MVA(PHT), MVA(PLN), and C(n) (r = -0.77, P < 0.0001), but the line of fit was nearly flat for the percentage difference among MVA(PISA), MVA(PLN), and C(n) (r = 0.1, P = 0.388).
CONCLUSION: MVA calculated with both the PISA and PHT methods correlated well with MVA calculated with the planimetry method. However, the PISA rather than PHT is recommended for patients with MS and extreme C(n) values because PISA, unlike PHT, is not affected by changes in C(n).