Pacing and clinical electrophysiology : PACE · 2008
Long-term follow-up of P-wave duration and dispersion in patients with mitral stenosis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Guntekin Unal, Gunes Yilmaz, Tuncer Mustafa, Gunes Ahmet, Sahin Musa, Simsek Hakki
Аннотация
BACKGROUND: Patients with mitral stenosis have prolonged P-wave duration and increased P-wave dispersion (PWD) that have been associated with increased risk for atrial fibrillation.
METHODS: Thirty mild-to-moderate mitral stenosis patients were followed for 38.4+/-10.7 (23-48) months. Baseline and last 12-lead electrocardiographic and transthoracic echocardiographic measurements were evaluated. Maximum and minimum P-wave durations (Pmax and Pmin) and PWD were calculated.
RESULTS: Pmax and PWD were significantly higher in patients compared to control group. Left atrial (LA) size, mitral gradient, and pulmonary artery systolic pressure (PASP) were significantly increased and mitral valve area (MVA) was decreased during follow-up. There were significant increases in Pmax and PWD and significant decrease in Pmin (Pmax: 101.0+/-12.5 ms vs 105.0+/-16.5 ms, P=0.005; Pmin: 59.3+/-8.5 ms vs 55.0+/-12.3 ms P=0.004; PWD: 41.7+/-5.5 ms vs 50.0+/-6.2 ms, P<0.001). Baseline Pmax, Pmin, and PWD were significantly correlated with MVA (Pmax: r=-0.605, P<0.001, Pmin: r=-0.632, P<0.001, PWD: r=-0.402, P=0.0028) and mean mitral gradient (Pmax: r=0.412, P=0.024, Pmin: r=0.632, P=0.049, PWD: r=0.378, P=0.039). In addition to MVA and mean mitral gradient follow-up P-wave variables were significantly correlated with LA size (Pmax: r=0.573, P=0.001, Pmin: r=0.636, P=0.001, PWD: r=0.265, P=0.046) and PASP (Pmax: r=0.462, P=0.011, Pmin: r=0.472, P=0.008 PWD: r=0.295, P=0.047).
CONCLUSIONS: P-wave duration and PWD increase progressively in accordance with the progression of mitral stenosis.
METHODS: Thirty mild-to-moderate mitral stenosis patients were followed for 38.4+/-10.7 (23-48) months. Baseline and last 12-lead electrocardiographic and transthoracic echocardiographic measurements were evaluated. Maximum and minimum P-wave durations (Pmax and Pmin) and PWD were calculated.
RESULTS: Pmax and PWD were significantly higher in patients compared to control group. Left atrial (LA) size, mitral gradient, and pulmonary artery systolic pressure (PASP) were significantly increased and mitral valve area (MVA) was decreased during follow-up. There were significant increases in Pmax and PWD and significant decrease in Pmin (Pmax: 101.0+/-12.5 ms vs 105.0+/-16.5 ms, P=0.005; Pmin: 59.3+/-8.5 ms vs 55.0+/-12.3 ms P=0.004; PWD: 41.7+/-5.5 ms vs 50.0+/-6.2 ms, P<0.001). Baseline Pmax, Pmin, and PWD were significantly correlated with MVA (Pmax: r=-0.605, P<0.001, Pmin: r=-0.632, P<0.001, PWD: r=-0.402, P=0.0028) and mean mitral gradient (Pmax: r=0.412, P=0.024, Pmin: r=0.632, P=0.049, PWD: r=0.378, P=0.039). In addition to MVA and mean mitral gradient follow-up P-wave variables were significantly correlated with LA size (Pmax: r=0.573, P=0.001, Pmin: r=0.636, P=0.001, PWD: r=0.265, P=0.046) and PASP (Pmax: r=0.462, P=0.011, Pmin: r=0.472, P=0.008 PWD: r=0.295, P=0.047).
CONCLUSIONS: P-wave duration and PWD increase progressively in accordance with the progression of mitral stenosis.