MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2008.03.050

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2008

Mitral valve motion after performing an edge-to-edge repair in an isolated swine heart.

Hasegawa Hiroki, Araki Yoshimori, Usui Akihiko, Yokote Jun, Saito Shunei, Oshima Hideki, Ueda Yuichi

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Mitral valve motion after performing an edge-to-edge repair is a major concern, but it has not yet been observed directly. Mitral valve motion was assessed by using a high-speed digital video camera and microsonometric analysis in an isolated swine heart, and any changes in the mitral valve area or the development of mitral stenosis symptoms were evaluated.

METHODS

A temporary edge-to-edge repair model was created. The mitral valve motion was assessed by using a high-speed digital video camera, and the motion of the mitral annulus was measured by means of sonomicrometric analysis with or without performing edge-to-edge repair (n = 5). The left ventricular volumetric measurements were also measured with a conductance catheter. One cardiac cycle was divided into 4 phases: the mitral valve open phase, the isovolumic contraction phase, the aortic valve open phase, and the isovolumic relaxation phase.

RESULTS

The mitral valve was divided into 2 orifices by using the edge-to-edge technique, and the mitral valve area decreased by approximately 30%. The ratio of mitral valve open phase significantly decreased (31.9% +/- 3.4% vs 41.4% +/- 3.7%, P = .04). There were no significant differences in the diameter and the changes of anteroposterior dimensions of the mitral annulus. The stroke volume and the peak positive and negative dp/dt values showed no obvious change, but dv/dt values increased slightly without significance after removing the edge-to-edge suture (118 +/- 25 vs 130 +/- 17 mL/s, P = .14).

CONCLUSIONS

The mitral valve area decreased slightly; however, edge-to-edge repair did not create symptomatic mitral stenosis and showed no adverse affects on cardiac function.

Для цитирования: Hasegawa Hiroki, Araki Yoshimori, Usui Akihiko, Yokote Jun, Saito Shunei, Oshima Hideki, Ueda Yuichi. Mitral valve motion after performing an edge-to-edge repair in an isolated swine heart.. The Journal of thoracic and cardiovascular surgery. 2008. DOI: 10.1016/j.jtcvs.2008.03.050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.