Computerized analysis of retinal vessel width and tortuosity in premature infants.

Wilson Clare M, Cocker Kenneth D, Moseley Merrick J, Paterson Carl, Clay Simon T, Schulenburg William E, Mills Monte D, Ells Anna L, Parker Kim H, Quinn Graham E, Fielder Alistair R, Ng Jeffrey

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To determine, with novel software, the feasibility of measuring the tortuosity and width of retinal veins and arteries from digital retinal images of infants at risk of retinopathy of prematurity (ROP).

METHODS

The Computer-Aided Image Analysis of the Retina (CAIAR) program was developed to enable semiautomatic detection of retinal vasculature and measurement of vessel tortuosity and width from digital images. CAIAR was tested for accuracy and reproducibility of tortuosity and width measurements by using computer-generated vessel-like lines of known frequency, amplitude, and width. CAIAR was then tested by using clinical digital retinal images for correlation of vessel tortuosity and width readings compared with expert ophthalmologist grading.

RESULTS

When applied to 16 computer-generated sinusoidal vessels, the tortuosity measured by CAIAR correlated very well with the known values. Width measures also increased as expected. When the CAIAR readings were compared with five expert ophthalmologists' grading of 75 vessels on 10 retinal images, moderate correlation was found in 10 of the 14 tortuosity output calculations (Spearman rho = 0.618-0.673). Width was less well correlated (rho = 0.415).

CONCLUSIONS

The measures of tortuosity and width in CAIAR were validated using sequential model vessel analysis. On comparison of CAIAR output with assessments made by expert ophthalmologists, CAIAR correlates moderately with tortuosity grades, but less well with width grades. CAIAR offers the opportunity to develop an automated image analysis system for detecting the vascular changes at the posterior pole, which are becoming increasingly important in diagnosing treatable ROP.

Для цитирования: Wilson Clare M, Cocker Kenneth D, Moseley Merrick J, Paterson Carl, Clay Simon T, Schulenburg William E, Mills Monte D, Ells Anna L, Parker Kim H, Quinn Graham E, Fielder Alistair R, Ng Jeffrey. Computerized analysis of retinal vessel width and tortuosity in premature infants.. Investigative ophthalmology & visual science. 2008. DOI: 10.1167/iovs.07-1353.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.