DOI 10.1001/archopht.125.11.1523

Медицинская библиотека · Archives of ophthalmology (Chicago, Ill. : 1960) · 2007

Accuracy of ROPtool vs individual examiners in assessing retinal vascular tortuosity.

Wallace David K, Freedman Sharon F, Zhao Zheen, Jung Sin-Ho

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

OBJECTIVE

To prospectively determine if tortuosity assessment by a computer program (ROPtool) that traces retinal blood vessels and measures their tortuosity was more accurate than that of individual pediatric ophthalmologists.

METHODS

One hundred eighty-five high-quality RetCam images from premature infants were circulated to 3 retinopathy of prematurity (ROP) experts and 3 other pediatric ophthalmologists ("examiners") who graded the tortuosity in each quadrant as normal, pre-plus, or plus. These same images were analyzed using ROPtool.

RESULTS

Using expert consensus as the standard, ROPtool's overall accuracy of 95% (175 of 185) for identifying tortuosity sufficient for plus disease was similar to that of examiner 1 (93%; 172 of 185; P = .50), examiner 2 (93%; 172 of 185; P = .50), and examiner 3 (91%; 168 of 185; P = .10). ROPtool's sensitivity of 97% (36 of 37) compared favorably with that of examiner 1 (65%; 24 of 37; P < .001), examiner 2 (70%; 26 of 37; P < .001), and examiner 3 (81%; 30 of 37; P = .06).

CONCLUSION

Computer-assisted analysis of retinal images can potentially reduce subjectivity in the diagnosis of plus disease and optimize timing of follow-up and treatment for ROP.

Для цитирования: Wallace David K, Freedman Sharon F, Zhao Zheen, Jung Sin-Ho. Accuracy of ROPtool vs individual examiners in assessing retinal vascular tortuosity.. Archives of ophthalmology (Chicago, Ill. : 1960). 2007. DOI: 10.1001/archopht.125.11.1523.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.