MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.knee.2020.01.015

Медицинская библиотека · The Knee · 2020

Two-dimensional/three-dimensional EOS™ imaging is reliable and comparable to traditional X-ray imaging assessment of knee osteoarthritis aiding surgical management.

Hau Melinda Yun Ting, Menon Dipen Karunakar, Chan Ronald Jing Ning, Chung Kwong Yin, Chau Wai Wang, Ho Ki Wai

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

X-ray imaging is the gold standard for assessing lower limb conditions and preoperative planning. A novel low-radiation-dose EOS™ imaging system enables full-length weight-bearing imaging in one session and three-dimensional (3D) reconstruction. Thus, it can improve assessment of limb deformities, preoperative planning and follow-up with lower radiation exposure. The objective of this study was to measure lower limbs from EOS™ images to determine its accuracy and reproducibility in comparison with long-leg X-ray images.

METHODS

Over a one-year period, twenty patients (forty lower limbs) with knee osteoarthritis were recruited from clinic. Thirty-five (five excluded due to knee prosthesis) two-dimensional- (2D) EOS™, 3D EOS™ and X-ray images were measured independently by four observers, measuring lower limb angles and lengths. On average, twelve weeks later, observers repeated measurements on 2D EOS™ and X-ray images.

RESULTS

A t-test comparing 2D EOS™ with X-ray images showed no significant difference in all angle and length measurements (P > 0.05). When analysing observers separately, all measurements showed no significant difference, apart from the femoral anatomic-mechanical angle (fAMA) from observer 2 (2D EOS™ fAMA 6.21° vs. X-ray fAMA 7.10°, P = 0.02). Intra-observer intraclass correlation coefficient (ICC) for 2D EOS™ and X-ray was 1.00 and 1.00, respectively, and inter-observer ICC was 1.00 and 0.99, respectively. A t-test comparing 2D- with 3D EOS™ images showed no significant difference in all measurements. A t-test comparing 3D EOS™ with X-ray images showed no significant difference in all measurements.

CONCLUSION

This study showed the EOS™ imaging system to be a valid alternative method of imaging lower limbs for alignment, measurements and preoperative arthroplasty planning.

Для цитирования: Hau Melinda Yun Ting, Menon Dipen Karunakar, Chan Ronald Jing Ning, Chung Kwong Yin, Chau Wai Wang, Ho Ki Wai. Two-dimensional/three-dimensional EOS™ imaging is reliable and comparable to traditional X-ray imaging assessment of knee osteoarthritis aiding surgical management.. The Knee. 2020. DOI: 10.1016/j.knee.2020.01.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.