Oh Seok, Jeong Myung Ho, Park Dae Sung, Kim Munki, Kim Jung Ha, Hyun Dae Young, Cho Kyung Hoon, Kim Min Chul, Sim Doo Sun, Hong Young Joon, Kim Ju Han, Ahn Youngkeun

Аннотация

RATIONALE: Despite technological advances in interventional cardiology during the last decades, many concerns remain regarding the narrowing and occlusion of the in-stent area. Particularly, polymer materials pose several problems, including chronic arterial inflammation, impaired arterial healing, and stent thrombosis. To avoid these complications, we invented the TIGEREVOLUTION stent with a cobalt-chromium alloy-based stent platform deposited with N-TiO2 film, which has demonstrated good biocompatibility. As this stent is not coated with polymer, it is expected to have decreased risk of stent thrombosis.

PATIENT CONCERNS: A 62-year-old Korean man visited our department because of angina. We commenced coronary angiography (CAG).

DIAGNOSIS: CAG revealed critical stenosis in the mid-portion of the right coronary artery, with a minimum lumen area of 1.08mm2 on optical coherence tomography (OCT).

INTERVENTION: Percutaneous coronary intervention was performed with implantation of a novel 3.5 × 26-mm polymer-free everolimus-eluting stent using nitrogen-doped titanium dioxide film (TIGEREVOLUTION® stent). Post-percutaneous coronary intervention OCT showed good stent expansion and apposition, and the patient was discharged successfully and uneventfully.

OUTCOMES: Eight months later, follow-up coronary angiography demonstrated good stent patency with no definitive evidence of in-stent restenosis, with thin stent strut coverage demonstrated on OCT.

LESSONS: We report the first case of TIGEREVOLUTION stent implantation with follow-up OCT at 8 months.