Circulation journal : official journal of the Japanese Circulation Society · 2022
Comparison of 1-Month and 12-Month Vessel Responses Between the Polymer-Free Biolimus A9-Coated Stent and the Durable Polymer Everolimus-Eluting Stent.
Сравнительное исследованиеСтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ishihara Takayuki, Mizote Isamu, Nakamura Daisuke, Okamoto Naotaka, Shiraki Tatsuya, Itaya Naoki, Tsujimura Takuya, Takahara Mitsuyoshi, Nakayoshi Takaharu, Iida Osamu, Hata Yosuke, Nishino Masami, Ueno Takafumi, Nakatani Daisaku, Hikoso Shungo, Nanto Shinsuke, Mano Toshiaki, Sakata Yasushi, COLLABORATION Investigators
Аннотация
BACKGROUND: A polymer-free biolimus A9-coated stent (PF-BCS) may achieve better arterial healing than a durable polymer drug-eluting stent owing to its polymer-free feature.
METHODS AND RESULTS: This multicenter, prospective, observational study enrolled 105 patients (132 lesions) who underwent PF-BCS (51 patients, 71 lesions) or durable polymer everolimus-eluting stent (DP-EES, 54 patients, 61 lesions) implantation. Serial coronary angioscopy (CAS) and optical coherence tomography (OCT) examinations were performed at 1 and 12 months, and the serial vessel responses were compared between PF-BCS and DP-EES. The primary outcome measure was the incidence of subclinical intrastent thrombus on CAS. The secondary outcome measures were: adequate strut coverage (≥40 μm) on OCT and maximum yellow color grade on CAS. The incidence of thrombus was high at 1 month (100% vs. 93%, P=0.091), but decreased at 12 months (18% vs. 25%, P=0.56), without a significant difference between PF-BCS and DP-EES. The adequate strut coverage rate was significantly higher (84±14% vs. 69±22%, P<0.001) and yellow color was significantly less intense (P=0.012) at 12 months in PF-BCS than in DP-EES; however, they were not significantly different at 1 month (adequate strut coverage: 47±21% vs. 50±17%, P=0.40; yellow color: P=0.99).
CONCLUSIONS: Although the thrombogenicity of PF-BCS was similar to that of DP-EES, the adequate coverage and plaque stabilization rates of PF-BCS were superior to those of DP-EES at 12 months.
METHODS AND RESULTS: This multicenter, prospective, observational study enrolled 105 patients (132 lesions) who underwent PF-BCS (51 patients, 71 lesions) or durable polymer everolimus-eluting stent (DP-EES, 54 patients, 61 lesions) implantation. Serial coronary angioscopy (CAS) and optical coherence tomography (OCT) examinations were performed at 1 and 12 months, and the serial vessel responses were compared between PF-BCS and DP-EES. The primary outcome measure was the incidence of subclinical intrastent thrombus on CAS. The secondary outcome measures were: adequate strut coverage (≥40 μm) on OCT and maximum yellow color grade on CAS. The incidence of thrombus was high at 1 month (100% vs. 93%, P=0.091), but decreased at 12 months (18% vs. 25%, P=0.56), without a significant difference between PF-BCS and DP-EES. The adequate strut coverage rate was significantly higher (84±14% vs. 69±22%, P<0.001) and yellow color was significantly less intense (P=0.012) at 12 months in PF-BCS than in DP-EES; however, they were not significantly different at 1 month (adequate strut coverage: 47±21% vs. 50±17%, P=0.40; yellow color: P=0.99).
CONCLUSIONS: Although the thrombogenicity of PF-BCS was similar to that of DP-EES, the adequate coverage and plaque stabilization rates of PF-BCS were superior to those of DP-EES at 12 months.