JACC. Case reports · 2024
Transcatheter Aspiration of Tricuspid Vegetation.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Brin Akiva, Dvir Danny, Harari Emanuel, Carasso Shemy, Wiener-Well Yonit, Glikson Michael, Hasin Tal
Аннотация
OBJECTIVE: This study sought to present the endovascular approach of transcatheter aspiration using the FlowTriever (Inari Medical) aspiration system for high surgical risk patients with right-sided infective endocarditis.
KEY STEPS: General anesthesia and transesophageal echocardiogram guidance; ultrasonography-guided femoral vein access, preclosure sutures, and insertion of a 24-F sheath; insertion of straight 24-F aspiration cannula over a stiff wire, parked in the superior vena cava; introduction of a 20-F curved cannula inside the 24-F cannula to create a telescopic assembly; accurate positioning using the right ventricle inflow/outflow projection in biplane mode; adjustment of the curved cannula radius by sliding the inner cannula in and out inside the mother cannula; manual aspiration of the vegetation; Postaspiration transesophageal echocardiogram assessment.
POTENTIAL PITFALLS: Avoid leaflet and annular injury and account for potential embolization.
TAKE-HOME MESSAGES: Endovascular aspiration using the aspiration system is an advanced therapeutic approach for high-risk patients with right-sided IE. The aggregative knowledge about transcatheter aspiration of tricuspid vegetation suggests a safe and effective procedural profile.
KEY STEPS: General anesthesia and transesophageal echocardiogram guidance; ultrasonography-guided femoral vein access, preclosure sutures, and insertion of a 24-F sheath; insertion of straight 24-F aspiration cannula over a stiff wire, parked in the superior vena cava; introduction of a 20-F curved cannula inside the 24-F cannula to create a telescopic assembly; accurate positioning using the right ventricle inflow/outflow projection in biplane mode; adjustment of the curved cannula radius by sliding the inner cannula in and out inside the mother cannula; manual aspiration of the vegetation; Postaspiration transesophageal echocardiogram assessment.
POTENTIAL PITFALLS: Avoid leaflet and annular injury and account for potential embolization.
TAKE-HOME MESSAGES: Endovascular aspiration using the aspiration system is an advanced therapeutic approach for high-risk patients with right-sided IE. The aggregative knowledge about transcatheter aspiration of tricuspid vegetation suggests a safe and effective procedural profile.