m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2022

Impact of diabetes on 1-year clinical outcome in patients undergoing revascularization with the BioFreedom stents or the Orsiro stents from the SORT OUT IX trial.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hansen Kirstine Nørregaard, Maeng Michael, Raungaard Bent, Engstrøm Thomas, Veien Karsten Tange, Kristensen Steen Dalby, Ellert-Gregersen Julia, Jensen Svend Eggert, Junker Anders, Kahlert Johnny, Jakobsen Lars, Christiansen Evald Høj, Jensen Lisette Okkels

Аннотация

This sub-study of the SORT OUT IX trial sought to compare clinical outcomes between patients with diabetes randomized to implantation of either the polymer-free biolimus A9-coated BioFreedom stent (BF-BES) or the ultra-thin strut, biodegradable polymer sirolimus-eluting Orsiro stent (O-SES). Patients with diabetes have an increased risk of target lesion failure (TLF) after percutaneous coronary intervention (PCI). The impact of different stent types in patients with diabetes is still discussed. A total of 607 of the 3151 patients (19.3%) enrolled in the SORT OUT IX study had diabetes. Randomization was stratified by patients with/without diabetes; 304 received BF-BES and 303 O-SES. The primary endpoint was TLF, which was a composite of cardiac death, myocardial infarction (not related to other than the index lesion) and target lesion revascularization (TLR) within 1 year. After 1 year, patients with diabetes had higher TLF (7.2% vs. 3.7%, incidence rate ratio [IRR]: 1.65; 95% confidence interval [CI]: 1.08-2.50), than patients without diabetes. TLF did not differ significantly between BF-BES and O-SES in patients with diabetes (8.2% vs. 6.3%, IRR: 1.17; 95% CI: 0.63-2.20). In patients with diabetes, cardiac death occurred in 2.3% of BF-BES and in 3.6% of O-SES (IRR: 0.58; 95% CI: 0.23-1.45) and TLR occurred in 5.3% and 2.3% of BF-BES and O-SES, respectively (IRR: 2.12; 95% CI: 0.81-5.56). Definite stent thrombosis rates of 1.3% were found in both stent types. Patients with diabetes had higher 1-year TLF rate after PCI compared to patients without diabetes, whereas TLF did not differ significantly between the two stent types BF-BES and O-SES in patients with diabetes.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты