m+Medelevator.RU
← Поиск публикаций
The British journal of ophthalmology · 2007

Degree of angle closure and extent of peripheral anterior synechiae: an anterior segment OCT study.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Su D H W, Friedman D S, See J L S, Chew P T K, Chan Y-H, Nolan W P, Smith S D, Huang D, Zheng C, Li Y, Foster P J, Aung T

Аннотация

AIMS: To evaluate the relationship between angle width as determined by anterior segment optical coherence tomography (AS-OCT) and the presence of peripheral anterior synechiae (PAS).

METHODS: This was a prospective observational case series in which 203 subjects with primary angle closure or open angles were recruited. Images of the nasal, temporal and inferior angles were obtained with AS-OCT in dark conditions. Subjects then underwent gonioscopy by an independent examiner who was masked to the AS-OCT findings. PAS were identified by gonioscopy and defined as abnormal adhesions of the iris to the angle that were at least half a clock hour in width and present to the level of the anterior trabecular meshwork or higher. The total clock hours of PAS were recorded.

RESULTS: Sixty-eight subjects (33.5%) were PACS, 76 subjects (37.4%) had PAC/PACG, 14 (6.9%) had primary open angle glaucoma, and 45 (22.2%) subjects were normal with open angles. There was a weak but significant correlation between the angle opening distance (AOD), trabecular iris space area (TISA) and angle recess area (ARA) with clock hours of PAS (Spearman's correlation coefficients = -0.30, -0.32 and -0.32, respectively, p<0.001). The mean values of the AOD, TISA and ARA in the nasal, temporal and inferior quadrants were significantly less in eyes with PAS compared with those without (p<0.001, Mann-Whitney U test). Analysis by quadrant showed that these parameters were smaller in the nasal and temporal quadrants in eyes with PAS (p<0.01).

CONCLUSIONS: Angle width determined by AS-OCT and the extent of PAS were weakly correlated, and angle width was significantly smaller in eyes with PAS.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты