Is the ISNT rule violated in early primary open-angle glaucoma--a scanning laser tomography study.

Sihota R, Srinivasan G, Dada T, Gupta V, Ghate D, Sharma A

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIMS: To evaluate the relevance of the ISNT rule with reference to the optic nerve head, in differentiating normal and early glaucoma eyes and neuroretinal rim (NRR) area ratios as measures of glaucomatous optic neuropathy by confocal scanning laser ophthalmoscopy (Heidelberg retina tomography (HRT) II).

METHODS

The study included 136 control eyes and 63 eyes of early primary open-angle glaucoma. Each patient underwent a complete ophthalmic examination, HRT II (software 2.01) and achromatic automated perimetry using the Humphrey field analyzer Full threshold program 30-2 or 24-2. Topographic HRT parameters (disc area and rim area) were compared between the groups. To assess the statistical significance of differences between the study groups, the Student's t-test was used.

RESULTS

The ISNT rule was applicable in 71% of normal eyes and 68% of early glaucoma eyes. The superior to inferior area ratio was 0.96+/-0.01 in the normal group and 0.90+/-0.02 in the glaucoma group. There was a loss of approximately a quarter of the NRR in the inferotemporal and superotemporal quadrants. The inferonasal sector showed the least loss of NRR (4.34%).

CONCLUSION

The inferior NRR is marginally wider than the superior NRR in about 2/3 of normal eyes, but could not be clinically appreciated in many of these. The characteristic configuration of a normal optic disc with the rim width being greatest in the inferior disc region followed by the superior disc region was maintained even in most patients with early glaucoma.

Для цитирования: Sihota R, Srinivasan G, Dada T, Gupta V, Ghate D, Sharma A. Is the ISNT rule violated in early primary open-angle glaucoma--a scanning laser tomography study.. Eye (London, England). 2007. DOI: 10.1038/sj.eye.6702798.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.