The British journal of ophthalmology · 2007
Evaluation of ocular surface temperature and retrobulbar haemodynamics by infrared thermography and colour Doppler imaging in patients with glaucoma.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Galassi Fernando, Giambene Barbara, Corvi Andrea, Falaschi Giacomo
Аннотация
BACKGROUND: Ocular surface temperature (OST) could berelated to retrobulbar haemodynamics in patients with glaucoma.
AIMS: To compare OST measurements in patients with glaucoma and healthy controls, and to investigate the correlation between OST, intraocular pressure (IOP) and retrobulbar haemodynamics in patients with glaucoma.
METHODS: 32 patients with primary open-angle glaucoma (POAG) and 40 controls were included in the study. The parameters considered both in patients with POAG and in controls were IOP and OST values measured by infrared ocular thermography. Colour Doppler imaging was used to determine haemodynamic parameters in ophthalmic artery (OA), central retinal artery (CRA) and short posterior ciliary arteries (SPCAs) in patients with POAG.
RESULTS: OST values were significantly lower in patients with POAG than in controls (p<0.001). OST was negatively related with resistivity index of OA (p<0.001), CRA (p = 0.001) and SPCAs (p<0.001), and positively related with end-diastolic velocity of OA (p = 0.02) and SPCAs (p = 0.05).
CONCLUSION: This study suggested that OST could be a marker of impaired retrobulbar haemodynamics in patients with glaucoma.
AIMS: To compare OST measurements in patients with glaucoma and healthy controls, and to investigate the correlation between OST, intraocular pressure (IOP) and retrobulbar haemodynamics in patients with glaucoma.
METHODS: 32 patients with primary open-angle glaucoma (POAG) and 40 controls were included in the study. The parameters considered both in patients with POAG and in controls were IOP and OST values measured by infrared ocular thermography. Colour Doppler imaging was used to determine haemodynamic parameters in ophthalmic artery (OA), central retinal artery (CRA) and short posterior ciliary arteries (SPCAs) in patients with POAG.
RESULTS: OST values were significantly lower in patients with POAG than in controls (p<0.001). OST was negatively related with resistivity index of OA (p<0.001), CRA (p = 0.001) and SPCAs (p<0.001), and positively related with end-diastolic velocity of OA (p = 0.02) and SPCAs (p = 0.05).
CONCLUSION: This study suggested that OST could be a marker of impaired retrobulbar haemodynamics in patients with glaucoma.