MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo.2006.099853

Медицинская библиотека · The British journal of ophthalmology · 2006

Retrobulbar haemodynamics and morphometric optic disc analysis in primary open-angle glaucoma.

Plange N, Kaup M, Weber A, Arend K O, Remky A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Previous studies confirmed reduced retrobulbar haemodynamics in primary open-angle glaucoma (POAG).

AIM: To investigate a correlation between retrobulbar haemodynamics and morphometric neuroretinal rim analysis in patients with POAG.

METHODS

51 patients with POAG (mean (standard deviation (SD)) age 65 (11) years) were included in this clinical study. Blood flow velocities (peak systolic velocity (PSV) and end-diastolic velocity (EDV)) of the ophthalmic artery, central retinal artery (CRA), posterior ciliary arteries (PCA) and central retinal vein were measured using colour Doppler imaging (Siemens Sonoline Sienna, Erlangen, Germany). Optic disc morphometry was carried out using scanning laser tomography (Heidelberg Retinal Tomograph II Heidelberg Egineering Heidelberg, Germany). The stereometric parameters of the neuroretinal rim (rim area, rim volume, cup shape measure and retinal nerve fibre layer (RNFL) cross-sectional area) were used for analysis.

RESULTS

The PSV of the CRA was significantly (p<0.001) correlated with rim area (r = 0.50) and rim volume (r = 0.51). The minimum velocities of the central retinal vein were significantly (p<0.001) correlated with rim volume (r = 0.56) and RNFL cross-sectional area (r = 0.49). No correlations were found for the flow velocities of the ophthalmic artery and PCAs.

CONCLUSION

Retrobulbar haemodynamics of the central retinal artery and vein are correlated with the neuroretinal rim damage in POAG.

Для цитирования: Plange N, Kaup M, Weber A, Arend K O, Remky A. Retrobulbar haemodynamics and morphometric optic disc analysis in primary open-angle glaucoma.. The British journal of ophthalmology. 2006. DOI: 10.1136/bjo.2006.099853.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.