m+Medelevator.RU
← Поиск публикаций
Critical care medicine · 1996

Efficacy of perfluorocarbon partial liquid ventilation in a large animal model of acute respiratory failure.

СтатьяПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Overbeck M C, Pranikoff T, Yadao C M, Hirschl R B

Аннотация

OBJECTIVE: To demonstrate the efficacy of partial perfluorocarbon liquid ventilation in large animal model of acute respiratory failure.

DESIGN: Prospective, randomized, controlled trial.

SETTING: Animal laboratory at a university medical center.

SUBJECTS: Ten adult sheep, weighing 53.0 +/- 2.8 kg.

INTERVENTIONS: After assessment of baseline physiologic data, acute respiratory failure was induced by right atrial injection of oleic acid (0.2 mL/kg). Five animals (partial liquid ventilation group) underwent sequential intratracheal dosing of 10 mL/kg of perflubron at 30-min intervals to the following cumulative doses: 10, 20, 30, 40, and 50 mL/kg. The remaining five animals were gas ventilated (control group). Physiologic data were assessed at 30-min intervals in both groups for the 2.5-hr experimental period or until death.

MEASUREMENTS AND MAIN RESULTS: When compared with control animals, intratracheal perfluorocarbon instillation resulted in significant improvements in arterial oxygen saturation (arterial oxygen saturation after 50 mL/kg: partial liquid ventilation, 96 +/- 3%; control, 55 +/- 8%; p = .001) and physiologic shunt (physiologic shunt after 50 mL/kg dose: partial liquid ventilation, 2 +/- 8%; control, 64 +/- 5%; p = .004). Oxygen delivery improved with perfluorocarbon instillation, but this improvement was not significant. No significant difference in pulmonary compliance was observed during partial liquid ventilation when compared with controls (pulmonary compliance: partial liquid ventilation, 0.43 +/- 0.04 mL/ cm H2O/kg; control, 0.53 +/- 0.03 mL/cm H2O/kg; p = .102).

CONCLUSIONS: Partial liquid ventilation with perflubron provides effective improvement in gas exchange in an adult animal model of respiratory failure.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты