Yamanaka Futoshi, Shishido Koki, Moriyama Noriaki, Ochiai Tomoki, Miyashita Hirokazu, Yokoyama Hiroaki, Sugiyama Yoichi, Yashima Fumiaki, Ohno Yohei, Nishina Hidetaka, Izumo Masaki, Asami Masahiko, Naganuma Toru, Mizutani Kazuki, Yamawaki Masahiro, Tada Norio, Shirai Shinichi, Noguchi Masahiko, Ueno Hiroshi, Takagi Kensuke, Watanabe Yusuke, Yamamoto Masanori, Saito Shigeru, Hayashida Kentaro, OCEAN-TAVI Investigators

СтатьяМногоцентровое исследованиеСравнительное исследованиеНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.

OBJECTIVES

This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.

METHODS

In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry. We analyzed 7,051 patients (median age = 85 years, 68.4% women) and identified 503 (7.1%) with bicuspid AS. We compared the incidence of PPM and long-term mortality in 497 patients with and 497 without bicuspid AS after one-to-one propensity score matching analysis.

RESULTS

Among the 7,051 patients, moderate and severe PPM were observed in 756 (10.7%) and 92 (1.3%) patients, respectively. Upon Kaplan-Meier curve analysis of the overall cohort, severe PPM appeared to be associated with long-term mortality (log-rank test, P = 0.065). After propensity score matching analysis, moderate and severe PPM were more frequently observed among patients with tricuspid AS than patients with bicuspid AS (moderate PPM, 11.7% vs 4.4%; severe PPM, 1.4% vs 1.0%; P = 0.0001).

CONCLUSIONS

Severe PPM appeared to be associated with all-cause mortality. Moderate and severe PPM were more frequently observed in patients with tricuspid AS than patients with bicuspid AS.

Для цитирования: Yamanaka Futoshi, Shishido Koki, Moriyama Noriaki, Ochiai Tomoki, Miyashita Hirokazu, Yokoyama Hiroaki, Sugiyama Yoichi, Yashima Fumiaki, Ohno Yohei, Nishina Hidetaka, Izumo Masaki, Asami Masahiko, Naganuma Toru, Mizutani Kazuki, Yamawaki Masahiro, Tada Norio, Shirai Shinichi, Noguchi Masahiko, Ueno Hiroshi, Takagi Kensuke, Watanabe Yusuke, Yamamoto Masanori, Saito Shigeru, Hayashida Kentaro, OCEAN-TAVI Investigators. Incidence and Prognosis of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement for Bicuspid Aortic Stenosis.. JACC. Cardiovascular interventions. 2025. DOI: 10.1016/j.jcin.2024.10.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.