Intensive care medicine · 1995
Elevated static compliance of the total respiratory system: early predictor of weaning unsuccess in severed COPD patients mechanically ventilated.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zanotti E, Rubini F, Iotti G, Braschi A, Palo A, Bruschi C, Fracchia C, Nava S
Аннотация
OBJECTIVE: To assess in a group of COPD patients mechanically ventilated for an episode of acute respiratory failure the respiratory mechanics with a simple and non invasive method at the bedside in order to evaluate if these parameters may be predictive of weaning failure or success.
DESIGN: A prospective study.
SETTING: Intensive care and intermediate intensive care units.
PATIENTS: 23 COPD patients ventilated for acute respiratory failure and studied within 24 hours from intubation.
METHODS: Using end-expiratory and end-inspiratory airway occlusion technique, we measured PEEPi, static compliance of the respiratory system (Crs, st) maximum respiratory resistance (Rrsmax) and minimum respiratory resistance (Rrsmin).
MEASUREMENTS AND RESULTS: The weaned group (A) and the not weaned group (B) were not different regarding to static PEEPi (group A 8.5 +/- 4.0 vs group B 8.9 +/- 2.6 cmH2O), TO Rrsmax (22.4 +/- 5.3 versus 22.2 +/- 9.0 cmH2O/1/s) and to Rrsmin (17.6 +/- 5.5 versus 17.9 +/- 8.0 cmH2O/1/s), while a significant difference (p < 0.001) has been found in Cst, rs (62.7 +/- 17.% versus 111.6 +/- 18.0 ml/cm H2O). The threshold value of 88.5 ml/cmH2O was identified by discriminant analysis and provided the best separation between the two groups, with a sensitivity of 0.85 and a specificity of 0.87.
CONCLUSION: Cst, rs measured non invasively in the first 24 h from intubation, provided a good separation between the patients who were successfully weaned and those who failed.
DESIGN: A prospective study.
SETTING: Intensive care and intermediate intensive care units.
PATIENTS: 23 COPD patients ventilated for acute respiratory failure and studied within 24 hours from intubation.
METHODS: Using end-expiratory and end-inspiratory airway occlusion technique, we measured PEEPi, static compliance of the respiratory system (Crs, st) maximum respiratory resistance (Rrsmax) and minimum respiratory resistance (Rrsmin).
MEASUREMENTS AND RESULTS: The weaned group (A) and the not weaned group (B) were not different regarding to static PEEPi (group A 8.5 +/- 4.0 vs group B 8.9 +/- 2.6 cmH2O), TO Rrsmax (22.4 +/- 5.3 versus 22.2 +/- 9.0 cmH2O/1/s) and to Rrsmin (17.6 +/- 5.5 versus 17.9 +/- 8.0 cmH2O/1/s), while a significant difference (p < 0.001) has been found in Cst, rs (62.7 +/- 17.% versus 111.6 +/- 18.0 ml/cm H2O). The threshold value of 88.5 ml/cmH2O was identified by discriminant analysis and provided the best separation between the two groups, with a sensitivity of 0.85 and a specificity of 0.87.