MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0196970

Медицинская библиотека · PloS one · 2018

Evaluation of tracer labelled methionine load test in vitamin B-12 deficient adolescent women.

Bhat Dattatray S, Gruca Lourdes L, Bennett Carole D, Katre Prachi, Kurpad Anura V, Yajnik Chittaranjan S, Kalhan Satish C

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Methionine loading test (MLT) has been used primarily to identify defects in transsulfuration of homocysteine in cystathionine beta synthase deficiency. It may not be as useful to evaluate remethylation pathway, in vitamin B-12 and folate deficiencies.

OBJECTIVE

We used tracer isotope labelled MLT to interrogate transsulfuration and remethylation independently in vitamin B-12 deficiency.

DESIGN

We studied vitamin B-12 deficient women with a tracer labelled MLT before and eleven months after treatment with vitamin B-12. The fractional contribution of [13C]homocysteine to breath CO2 was used as a measure of transsulfuration, and difference in the intracellular enrichment of [13C]methionine and that of [C2H3]methionine as a measure of remethylation of homocysteine. Combined pre- and post-treatment results were analyzed to investigate the association between plasma vitamin B-12 concentrations and measures of homocysteine metabolism.

RESULTS

The subjects were 17 years old, with a BMI of 19.4 kg/m2. Treatment with vitamin B-12, 2µg/day increased plasma B-12 from 93 (78.7, 106.2) [median (25th, 75th centiles)] to 161.5 (125.5, 226.2) pmol/L; 44% were below <150pmol/L after treatment. Fasting homocysteine concentration was significantly lower and that of cysteine higher in subjects with B-12 levels >150pmol/L. The tracer estimated transsulfuration of homocysteine was lower and remethylation higher with B-12 levels >150pmol/L when compared with those <150pmol/L.

CONCLUSIONS

The tracer labelled MLT in combination with fasting parameters is a robust way to estimate parameters of methionine metabolism and can be used in the field where prime-constant rate infusion studies cannot be done efficiently.

Для цитирования: Bhat Dattatray S, Gruca Lourdes L, Bennett Carole D, Katre Prachi, Kurpad Anura V, Yajnik Chittaranjan S, Kalhan Satish C. Evaluation of tracer labelled methionine load test in vitamin B-12 deficient adolescent women.. PloS one. 2018. DOI: 10.1371/journal.pone.0196970.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.