MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00004424-200210000-00001

Медицинская библиотека · Investigative radiology · 2002

Time-resolved contrast-enhanced magnetic resonance angiography of the carotid arteries: diagnostic accuracy and inter-observer variability compared with selective catheter angiography.

Lenhart Markus, Framme Nicola, Völk Markus, Strotzer Michael, Manke Christoph, Nitz Wolfgang R, Finkenzeller Thomas, Feuerbach Stefan, Link Johann

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

To assess the diagnostic accuracy and interobserver variability of contrast-enhanced magnetic resonance angiography (CE-MRA) in a time-resolved technique compared with digital subtraction angiography (x-ray DSA) in patients with suspected stenoses of the internal carotid artery.

MATERIALS AND

METHODS

A total of 43 patients were enrolled in this prospective study. All patients underwent selective x-ray DSA involving a total of 84 carotid arteries. CE-MRA was performed in a time-resolved technique with a fast gradient-echo sequence on a 1.5 T MR scanner: TR 3.8 milliseconds, TE 1.49 milliseconds. Four consecutive measurements, each a duration of 10 seconds, were performed with omission of measuring bolus transit time. Four independent radiologists scored the degree of stenosis. The interobserver variability was calculated for CE-MRA and x-ray DSA.

RESULTS

In the 43 cases, at least one MRA measurement showed arterial contrast without venous degradation. Compared with x-ray DSA the mean sensitivity and specificity for grading stenosis > or = 70% were 98% and 86%, respectively. The interobserver agreement was substantial with no significant difference between CE-MRA (kappa value 0.794) and x-ray DSA (kappa value 0.786).

CONCLUSIONS

The short acquisition time of a fast CE-MRA sequence allows a selective visualization of the internal carotid arteries without degradation from venous enhancement. It is a reliable method with a good interobserver agreement.

Для цитирования: Lenhart Markus, Framme Nicola, Völk Markus, Strotzer Michael, Manke Christoph, Nitz Wolfgang R, Finkenzeller Thomas, Feuerbach Stefan, Link Johann. Time-resolved contrast-enhanced magnetic resonance angiography of the carotid arteries: diagnostic accuracy and inter-observer variability compared with selective catheter angiography.. Investigative radiology. 2002. DOI: 10.1097/00004424-200210000-00001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.