MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12149-022-01784-y

Медицинская библиотека · Annals of nuclear medicine · 2022

Semiquantitative analysis using whole-body dynamic F-18 fluoro-2-deoxy-glucose-positron emission tomography to differentiate between benign and malignant lesions.

Watanabe Mirei, Kato Hiroki, Katayama Daisuke, Soeda Fumihiko, Matsunaga Keiko, Watabe Tadashi, Tatsumi Mitsuaki, Shimosegawa Eku, Tomiyama Noriyuki

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To investigate whether whole-body dynamic positron emission tomography (PET) is useful for differentiating benign and malignant lesions.

METHODS

In this retrospective study, data from a cohort of 146 lesions from 187 patients who consecutively underwent whole-body dynamic PET scans at our hospital for suspected lesions in the lung, lymph nodes, liver, bone, esophagus, and colon were analyzed. Patients with malignant lymphomas, accumulations > 5 cm in length along the long axis of the esophagus, or lesions in the colon in which the site of accumulation moved during the imaging period were excluded. Patients were administered 3.7 MBq/kg of fluorine-18-fluorodeoxyglucose (F-18 FDG), and dynamic imaging was initiated 60 min after administration. We defined the 60-65, 65-70, 70-75, and 75-80 min time mark as the first, second, third, and fourth pass, respectively. The static image is the summed average of all the four pass images. We measured the accumulation in the mean image of the whole-body dynamic PET scan, which was arithmetically similar to the maximum standardized uptake value (SUVmax) throughout the whole-body static images obtained during 20 min of imaging (S-SUVmax). The ratio of SUVmax in the dynamic first pass(60-65 min after FDG administration) and fourth pass(75-80 min after FDG administration) was calculated as R-SUVmax.

RESULTS

The S-SUVmax in the lung, lymph nodes, and bone did not differ significantly between the benign and malignant groups. However, there was a significant difference in R-SUVmax, which was > 1 in most malignant lesions indicating an increase in accumulation during routine scan time. Significant differences were observed between benign and malignant lesions of the liver in both S-SUVmax and R-SUVmax values, with the latter being > 1 in most malignant lesions.

CONCLUSIONS

Whole-body dynamic PET for 20 min starting 1 h after FDG administration improved the accuracy of malignant lesion detection in the liver, lymph nodes, lung, and bone. The incremental improvement was small, and the FDG dynamics in the distribution of values between benign and malignant overlapped. Additional information from whole-body dynamic imaging can help detect malignant lesions in these sites without increasing patient burden or prolonging imaging time.

Для цитирования: Watanabe Mirei, Kato Hiroki, Katayama Daisuke, Soeda Fumihiko, Matsunaga Keiko, Watabe Tadashi, Tatsumi Mitsuaki, Shimosegawa Eku, Tomiyama Noriyuki. Semiquantitative analysis using whole-body dynamic F-18 fluoro-2-deoxy-glucose-positron emission tomography to differentiate between benign and malignant lesions.. Annals of nuclear medicine. 2022. DOI: 10.1007/s12149-022-01784-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.