DOI 10.3928/1081597x-20130129-06
Factors affecting near vision after monofocal intraocular lens implantation.
Аннотация
PURPOSE: To identify factors that influence near vision after monofocal intraocular lens (IOL) implantation for distance vision.
METHODS
A retrospective review was conducted of patients who underwent cataract surgery with monofocal IOL implantation from October 2009 to April 2010 at Samsung Medical Center. Eyes were classified as having good (⩾ J4) or poor (< J4) near vision. Factors analyzed included age, sex, intraocular lens (IOL) movement, axial length, pupil size, degree and type of astigmatism, IOL type, total aberration, and higher-order aberrations. Binary logistic regression and odds ratios with 95% confidence intervals were determined.
RESULTS
This retrospective study involved 84 eyes of 84 patients. Thirty-four eyes were classified as having good near vision and 50 eyes as having poor near vision. All groups had a postoperative uncorrected visual acuity greater than 0.2 logMAR (Snellen 20/32) and a refractive error within ± 0.5 diopter of spherical equivalent. Pupil size and axial length were inversely associated with good near vision (P = .034 and .039, respectively). A pupil size smaller than 2.6 mm and an axial length less than 23.0 mm resulted in better near vision than larger measurements after monofocal IOL implantation for distant target.
CONCLUSIONS
Among the factors analyzed, small pupil size and short axial length predicted good near vision after phacoemulsification and monofocal IOL implantation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.