American journal of ophthalmology · 2013
Laser-assisted in situ keratomileusis in high mixed astigmatism with optimized, fast-repetition and cyclotorsion control excimer laser.
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Alio Jorge L, Pachkoria Ketevan, El Aswad Amr, Plaza-Puche Ana Belen
Аннотация
PURPOSE: To evaluate the visual refractive and aberrometric outcomes of laser-assisted in situ keratomileusis (LASIK) surgery for the correction of high mixed astigmatism using a new-generation excimer laser and optimized aspherical profiles.
DESIGN: Retrospective interventional case series.
METHODS: Fifty-two eyes of 36 patients (21-53 years) with primary mixed astigmatism over 3.0 diopters (D) were included. All cases underwent LASIK surgery using the sixth-generation excimer laser Amaris with cyclotorsion control and a femtosecond platform for flap creation. Visual, refractive, corneal topographic, and aberrometric outcomes were evaluated during a 3-month follow-up. Refractive astigmatic changes were analyzed by Alpins method.
RESULTS: A significant reduction of refractive sphere and cylinder was observed 3 months postoperatively (P = .001), with an associated improvement of uncorrected distance visual acuity (P = .001). Best-corrected distance visual acuity (CDVA) remained unchanged in 31 eyes (59.6%), while 3 eyes (5.76%) lost 2 lines of CDVA. Fourteen eyes (26.9%) had spherical equivalent (SE) within ±0.5 D of emmetropia and 34 (65.3%) had SE within ±1.0 D of emmetropia. No significant difference was observed when comparing surgically induced and target astigmatism. A significant induction of higher-order aberration attributable to increase of spherical aberration was found (P = .003). Seven eyes (13.4%) required retreatment.
CONCLUSIONS: LASIK for primary high mixed astigmatism using optimized aspherical profiles and a fast-repetition-rate excimer laser with cyclotorsion control is a safe, effective, and predictable procedure. Induction of higher-order aberrations is still present in the correction of the refraction error of the magnitude included in this study.
DESIGN: Retrospective interventional case series.
METHODS: Fifty-two eyes of 36 patients (21-53 years) with primary mixed astigmatism over 3.0 diopters (D) were included. All cases underwent LASIK surgery using the sixth-generation excimer laser Amaris with cyclotorsion control and a femtosecond platform for flap creation. Visual, refractive, corneal topographic, and aberrometric outcomes were evaluated during a 3-month follow-up. Refractive astigmatic changes were analyzed by Alpins method.
RESULTS: A significant reduction of refractive sphere and cylinder was observed 3 months postoperatively (P = .001), with an associated improvement of uncorrected distance visual acuity (P = .001). Best-corrected distance visual acuity (CDVA) remained unchanged in 31 eyes (59.6%), while 3 eyes (5.76%) lost 2 lines of CDVA. Fourteen eyes (26.9%) had spherical equivalent (SE) within ±0.5 D of emmetropia and 34 (65.3%) had SE within ±1.0 D of emmetropia. No significant difference was observed when comparing surgically induced and target astigmatism. A significant induction of higher-order aberration attributable to increase of spherical aberration was found (P = .003). Seven eyes (13.4%) required retreatment.
CONCLUSIONS: LASIK for primary high mixed astigmatism using optimized aspherical profiles and a fast-repetition-rate excimer laser with cyclotorsion control is a safe, effective, and predictable procedure. Induction of higher-order aberrations is still present in the correction of the refraction error of the magnitude included in this study.