MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2012.10.045

Медицинская библиотека · Journal of cataract and refractive surgery · 2013

Laser in situ keratomileusis for high hyperopia (>5.0 diopters) using optimized aspheric profiles: efficacy and safety.

Alió Jorge L, El Aswad Amr, Vega-Estrada Alfredo, Javaloy Jaime

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the clinical outcomes of laser in situ keratomileusis (LASIK) for high hyperopia using an excimer laser and optimized aspheric profiles.

SETTING

Vissum Corporation and Miguel Hernández University, Alicante, Spain, and Research Institute of Ophthalmology, Giza, Egypt.

DESIGN

Case series.

METHODS

Eyes of patients with high hyperopia or hyperopic astigmatism (spherical equivalent [SE] ≥ 5.64 diopters [D]) had uneventful LASIK with an aspheric optimized ablation profile centered on the corneal vertex using an Amaris 500 kHz excimer laser and a femtosecond platform for flap creation with a temporal hinge.

RESULTS

There was a significant improvement in uncorrected distance visual acuity 3 months postoperatively (P<.01), with no significant changes afterward (P=.72). At 6 months, the corrected distance visual acuity (CDVA) remained unchanged or improved in 90.48% of eyes; 2 eyes (9.52%) lost 2 lines of logMAR CDVA. The postoperative SE was within ± 0.50 D of emmetropia in 70.37% of eyes. The LASIK enhancement rate at the end of the follow-up was 29.4%. Significant induction of corneal primary spherical aberration and coma was found with 6.0 mm pupils (P<.01). The safety index was 0.94 and the efficacy index, 0.85.

CONCLUSION

Laser in situ keratomileusis for high hyperopia using optimized aspheric profiles requires further improvement in terms of safety but was still an effective and a predictable procedure.

Для цитирования: Alió Jorge L, El Aswad Amr, Vega-Estrada Alfredo, Javaloy Jaime. Laser in situ keratomileusis for high hyperopia (>5.0 diopters) using optimized aspheric profiles: efficacy and safety.. Journal of cataract and refractive surgery. 2013. DOI: 10.1016/j.jcrs.2012.10.045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.