m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2012

Fluctuations in corneal curvature limit predictability of intraocular lens power calculations.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Norrby Sverker, Hirnschall Nino, Nishi Yutaro, Findl Oliver

Аннотация

PURPOSE: To analyze fluctuations in corneal curvature over time.

SETTING: Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom.

DESIGN: Case series.

METHODS: A 3-piece IOL was implanted in 1 eye and a 1-piece IOL in the other eye through a 3.2 mm clear corneal temporal incision. Keratometry was performed preoperatively and at several points in time postoperatively. Differences between measurements were analyzed by power vectors. Statistical significance was assessed by monovariate, bivariate, and trivariate paired t tests. Acute angle shifts were determined as differences between meridians at 2 points in time.

RESULTS: Fifty patients were enrolled. From preoperatively to 1 year postoperatively, the changes in vector components (M, J0, J45) were, respectively, -0.02 diopter (D) ± 0.23 (SD) (P=.38), -0.07 ± 0.27 D (P=.02), and +0.04 ± 0.25 D (P=.14). Corresponding changes from 1 year to 2 years postoperatively were +0.01 ± 0.25 D (P=.73), +0.01 ± 0.23 D (P=.83), and +0.01 ± 0.16 D (P=.40). The meridian shift was -5 ± 32 degrees (P=.13) from preoperatively to postoperatively and +3 ± 22 degrees (P=.23) from 1 year to 2 years.

CONCLUSIONS: Surgically induced astigmatism was composed of slight flattening in the horizontal meridian and slight steepening in the oblique meridian but was insignificant in relation to random fluctuations, which were almost equally large between postoperative measurements 1 year apart. The fluctuations were not due to imprecision in measurement.

FINANCIAL DISCLOSURE: Dr. Norrby is a retiree from Abbott Medical Optics, Inc., and holder of a small amount of stock. Dr. Findl is scientific advisor to Abbott Medical Optics, Inc. No other author has a financial or proprietary interest in any material or method mentioned.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты