m+Medelevator.RU
← Поиск публикаций
Khirurgiia · 2023

[The first experience of fluorescent angiography with indocyanine green in primary esophagoplasty with gastric conduit in patients with malignant tumors of the esophagus].

Аннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dvoretsky S Yu, Kapshuk Ya Yu, Komarov I V, Akopov A L

Аннотация

OBJECTIVE: To evaluate the possibilities of intraoperative indocyanine green fluorescein angiography (ICG technology) in primary esophagoplasty by gastric conduit in patients with malignant tumors of the esophagus.

MATERIAL AND METHODS: The study included 74 patients. Depending on the localization of the tumor in the esophagus, a Lewis-type or McKeown-type operation was performed. The retrospective group (surgery without the use of ICG technology) included 53 patients who underwent surgery from 2015 to 2020 years.The prospective group (surgery with the use ICG technology) included 21 patients operated on from 2021 to 2023 years. ICG technology was used to assess microcirculation in the gastric conduit during esophagoplasty, as well as to identify the right gastroepiploic artery.

RESULTS: The ICG fluorescein angiography technique for assessing microcirculation in the gastric conduit was a simple and easily reproducible procedure. Perfusion of the gastric conduit was regarded as satisfactory in 16 (76%) cases, unsatisfactory in 5 (24%) cases, which required resection of the distal part of the conduit. All cases of poor perfusion were in patients with narrow gastric conduit and neck anastomosis location (McKeown-type operation). Anastomotic leakages occurred in 8 (15%) patients in the retrospective group, 4 (19%) patients in the prospective group (p>0.05). In 4 out of 5 cases of poor gastric conduit perfusion, anastomotic leaks occurred. Immediate postoperative results in the compared groups were also comparable. The use of ICG technology in 5 (45%) cases out of 11, when laparoscopic mobilization of the stomach was performed, helped to visualize the right gastroepiploic artery, which is the main source of blood supply to the formed gastric conduit. The use of ICG technology in 3 patients with a compromised gastrostomy stomach demonstrated the absence of significant microcirculation disorders in the stomach wall.

CONCLUSION: The first experience of using fluorescein angiography with ICG in primary esophagoplasty by gastric conduit in patients with malignant tumors of the esophagus demonstrated the safety, simplicity and availability of this technique. An objective assessment of the effectiveness of the application of ICG technology requires the accumulation of experience.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты