m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2012

Wavefront-optimized excimer laser in situ keratomileusis for myopia and myopic astigmatism: refractive outcomes and corneal densitometry.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fares Usama, Otri Ahamd Muneer, Al-Aqaba Mouhamed Ali, Faraj Lana, Dua Harminder S

Аннотация

PURPOSE: To determine the refractive outcomes of wavefront-optimized laser in situ keratomileusis (LASIK) treatments, in particular to measure corneal densitometry after LASIK using the densitometry function of the Pentacam Scheimpflug system.

SETTING: Division of Ophthalmology and Visual Sciences, University of Nottingham, United Kingdom.

DESIGN: Cohort study.

METHODS: Changes in postoperative visual acuity, refraction, and contrast sensitivity were evaluated after wavefront-optimized laser treatment. Corneal densitometry was evaluated with the Scheimpflug system before and after LASIK.

RESULTS: One year postoperatively, the uncorrected distance visual acuity was 6/6 or better in 92% of eyes and 6/9 or better in all eyes. Eighty-six percent of eyes had no change in the corrected distance visual acuity (CDVA); 4% gained 1 or more lines. Wavefront-optimized LASIK was stable over 1 year postoperatively. Eighty-nine percent of eyes were within ±0.50 diopter (D) and 100% were within ±1.00 D of the intended correction 1 year postoperatively. Contrast sensitivity showed a nonsignificant improvement (1.55 ± 0.10 [SD] preoperatively to 1.57 ± 0.09 12 months postoperatively) (P > .05). There was a nonsignificant increase in corneal densitometry 1 year postoperatively (from 12.72 ± 2.43 to 13.04 ± 2.58) (P > .05). No correlation was found between corneal densitometry and contrast sensitivity or CDVA.

CONCLUSIONS: Wavefront-optimized LASIK gave excellent refractive and visual outcomes and did not seem to affect corneal densitometry significantly 1 year postoperatively. However, larger studies may show a masked effect on corneal densitometry.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты